Your browser doesn't support javascript.
loading
Development of a solid-phase microextraction method for fast analysis of cyclic volatile methylsiloxanes in water.
Zhang, Lifang; Jiang, Ruifen; Li, Wanbin; Muir, Derek C G; Zeng, Eddy Y.
Afiliação
  • Zhang L; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, China.
  • Jiang R; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, China. Electronic address: jiangrf5@jnu.edu.cn.
  • Li W; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, China.
  • Muir DCG; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, China; Environment and Climate Change Canada, 867 Lakeshore Road, Burlington, Ontario, L7S1A1, Canada.
  • Zeng EY; Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 511443, China.
Chemosphere ; 250: 126304, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32120150
ABSTRACT
Cyclic volatile methylsiloxanes (cVMS) are widely used in consumer products and commonly detected in the environment. There are challenges in the analysis of cVMS because of their ubiquitous use which can introduce high background contamination. The current study introduces a sample preparation method based on headspace of solid-phase microextraction (SPME) for monitoring the cVMS in waters. Efforts were made to reduce the background contamination during sample preparation and instrument analysis. A laboratory prepared MIL-101 coating was prepared using polysulfone instead of polydimethylsiloxane as adhesive to avoid the contamination. The extraction performance of the MIL-101 fiber was optimized and evaluated. The optimized extraction time and temperature were 60 min and 40 °C, respectively. The method quantification limits of the MIL-101 fiber for octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecylcyclohexasiloxane (D6) in water were 0.15 ng mL-1, 0.14 ng mL-1, and 0.27 ng mL-1, respectively. The extraction efficiency of the proposed MIL-101 fiber was comparable to the commercial polydimethylsiloxane/divinylbenzene fiber. The developed method was applied to analyze the cVMS in wastewater treatment plant and the concentrations in the barscreen and in the aeration tank ranged from 0.73 to 3.3 ng mL-1 and 7.74-85.1 ng mL-1, respectively. The MIL-101 fiber was also applied to study the photodegradation of the cVMS in water under simulated sunlight. Approximately 25%, 20%, and 45% of D4, D5, and D6, respectively, were degraded after 10 h exposure.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Siloxanas / Poluentes Químicos da Água / Microextração em Fase Sólida Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Siloxanas / Poluentes Químicos da Água / Microextração em Fase Sólida Idioma: En Ano de publicação: 2020 Tipo de documento: Article