Your browser doesn't support javascript.
loading
Transcatheter aortic valve replacement with the balloon-expandable SAPIEN 3 valve: Impact of calcium score on valve performance and clinical outcomes.
Guimarães, Leonardo; Ferreira-Neto, Alfredo Nunes; Urena, Marina; Nombela-Franco, Luis; Wintzer-Wehekind, Jerome; Levesque, Marie-Helene; Himbert, Dominique; Fischer, Quentin; Armijo, German; Vera, Rafael; Kalavrouziotis, Dimitri; Rodés-Cabau, Josep.
Afiliação
  • Guimarães L; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada.
  • Ferreira-Neto AN; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada.
  • Urena M; Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Paris, France.
  • Nombela-Franco L; Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain.
  • Wintzer-Wehekind J; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada.
  • Levesque MH; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada.
  • Himbert D; Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Paris, France.
  • Fischer Q; Assistance Publique-Hôpitaux de Paris, Bichat Hospital, Paris, France.
  • Armijo G; Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain.
  • Vera R; Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain.
  • Kalavrouziotis D; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada.
  • Rodés-Cabau J; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada. Electronic address: josep.rodes@criucpq.ulaval.ca.
Int J Cardiol ; 306: 20-24, 2020 05 01.
Article em En | MEDLINE | ID: mdl-32139241
ABSTRACT

BACKGROUND:

Aortic valve calcification severity has been associated with higher rates of aortic regurgitation (AR) following TAVR, but scarce data exist on its impact with the use of newer generation transcatheter heart valves.

METHODS:

This was a multicenter study including 626 patients with severe aortic stenosis who underwent TAVR with the SAPIEN 3 valve. Patients were divided in 2 groups according to the median index calcium score (iCS) for each sex high CS (HCS, iCS ≥ median), and low iCS (LCS, iCS < median). Another analysis was performed in those patients with extreme iCS (ECS, iCS >75th percentile for each sex). Clinical and echocardiographic data were collected prospectively in a dedicated database.

RESULTS:

The mean CS was 3758 ±â€¯1417 AU and 1616 ±â€¯691 AU in the HCS and LCS groups, respectively (p < 0.001). There were no differences between groups in 30-day mortality (HCS2.6%, LCS1.0%, p = 0.13) and stroke (HCS2.6%,LCS2.6%, p = 1.0) rates, but all cases (n = 5) of annulus rupture occurred in the HCS group (1.6% vs. 0%, p = 0.061). The incidence of moderate-severe AR post-TAVR was low in both groups (HCS1.6%,LCS1.6%, p = 1.0), and valve gradient and area were similar between groups. The results remained similar in the ECS group (mean CS4607 ±â€¯1424 AU), but a mildly increased mean transvalvular gradient post-TAVR was observed in ECS patients (12.1 ±â€¯5.6 vs 11.0 ±â€¯4.3 mmHg; p = 0.015).

CONCLUSION:

Aortic valve calcification severity failed to impact mortality/stroke rates following TAVR with the SAPIEN 3 valve. Low rates of significant AR were observed irrespective of CS, and a mild increase in transvalvular gradient was observed in ECS patients.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2020 Tipo de documento: Article