Your browser doesn't support javascript.
loading
Retention Modelling of Phenoxy Acid Herbicides in Reversed-Phase HPLC under Gradient Elution.
Biancolillo, Alessandra; Maggi, Maria Anna; Bassi, Sebastian; Marini, Federico; D'Archivio, Angelo Antonio.
Afiliação
  • Biancolillo A; Dipartimento di Scienze Fisiche e Chimiche, Università degli Studi dell'Aquila, Via Vetoio, Coppito, 67100 L'Aquila (AQ), Italy.
  • Maggi MA; Hortus Novus srl, Via Campo Sportivo 2, Canistro, 67100 L'Aquila, Italy.
  • Bassi S; Dipartimento di Chimica, Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Roma, Italy.
  • Marini F; Dipartimento di Chimica, Università degli Studi di Roma "La Sapienza", Piazzale Aldo Moro 5, 00185 Roma, Italy.
  • D'Archivio AA; Dipartimento di Scienze Fisiche e Chimiche, Università degli Studi dell'Aquila, Via Vetoio, Coppito, 67100 L'Aquila (AQ), Italy.
Molecules ; 25(6)2020 Mar 11.
Article em En | MEDLINE | ID: mdl-32168813
ABSTRACT
Phenoxy acid herbicides are used worldwide and are potential contaminants of drinking water. Reversed phase high-performance liquid chromatography (RP-HPLC) is commonly used to monitor phenoxy acid herbicides in water samples. RP-HPLC retention of phenoxy acids is affected by both mobile phase composition and pH, but the synergic effect of these two factors, which is also dependent on the structure and pKa of solutes, cannot be easily predicted. In this paper, to support the setup of RP-HPLC analysis of phenoxy acids under application of linear mobile phase gradients we modelled the simultaneous effect of the molecular structure and the elution conditions (pH, initial acetonitrile content in the eluent and gradient slope) on the retention of the solutes. In particular, the chromatographic conditions and the molecular descriptors collected on the analyzed compounds were used to estimate the retention factor k by Partial Least Squares (PLS) regression. Eventually, a variable selection approach, Genetic Algorithms, was used to reduce the model complexity and allow an easier interpretation. The PLS model calibrated on the retention data of 15 solutes and successively tested on three external analytes provided satisfying and reliable results.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenilacetatos / Ácidos Picolínicos / Poluentes Químicos da Água / Benzoatos / Ácido 2,4-Diclorofenoxiacético / Herbicidas Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenilacetatos / Ácidos Picolínicos / Poluentes Químicos da Água / Benzoatos / Ácido 2,4-Diclorofenoxiacético / Herbicidas Idioma: En Ano de publicação: 2020 Tipo de documento: Article