Ti-15Mo Alloy Decreases the Stress Concentration in Mandibular Angle Fracture Internal Fixation Hardware.
Guastaldi, F P S; Martini, A P; Rocha, E P; Hochuli-Vieira, E; Guastaldi, A C.
Afiliação
  • Guastaldi FPS; 1Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University (Unesp), Humaitá Street, 1680, Araraquara, SP 14801-903 Brazil.
  • Martini AP; 2Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University (Unesp), Araçatuba, SP Brazil.
  • Rocha EP; 2Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University (Unesp), Araçatuba, SP Brazil.
  • Hochuli-Vieira E; 1Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University (Unesp), Humaitá Street, 1680, Araraquara, SP 14801-903 Brazil.
  • Guastaldi AC; 3Department of Physical Chemistry, Institute of Chemistry, São Paulo State University (Unesp), Araraquara, SP Brazil.
J Maxillofac Oral Surg ; 19(2): 314-320, 2020 Jun.
Article em En | MEDLINE | ID: mdl-32346246
OBJECTIVES: Comparison of the mechanical stability of 2.0 plates made of commercially pure titanium (cpTi) and a titanium-molybdenum (Ti-15Mo) alloy and two methods of internal fixation employed mandibular angle fractures, using 3D finite element analysis. MATERIALS AND METHODS: Four groups were evaluated. For the cpTi: group Eng 1P, one 4-hole plate and 4 screws 6 mm long, in the tension zone of the mandible; group Eng 2P, two 4-hole plates, one in the tension zone of the mandible and the other in the compression zone, both were fixed with 8 screws 6 mm long. The same groups were created for the Ti-15Mo alloy. A 100 N compressive load was applied to the occlusal surface of the mandibular first molar on the plated side. RESULTS: When considering the von Mises equivalent stress (σ vM) values for the comparison between both groups with one plate, a decrease of 10.5% in the plate and a decrease of 29.0% in the screws for the Ti-15Mo group was observed. Comparing the same groups with two plates, a decrease of 28.5% in the screws was shown for the Ti-15Mo alloy group. No significant differences were observed when considering maximum and minimum principal stresses (σ max, σ min), and maximum principal strain (ε max) to the mandibular bone. The Ti-15Mo alloy plates substantially decreased the stress concentration in the screws for both internal fixation techniques and in the plate for the Ti-15Mo 1 plate group. CONCLUSION: From a clinical standpoint, the use of Ti-Mo alloy with reduced stiffness will decrease the stress shielding between the hardware and bone, influencing the outcome of the treatment.