Your browser doesn't support javascript.
loading
Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation.
Byun, Seong-Eun; Vintimilla, David R; Bedeir, Yehia H; Dean, Chase S; Parry, Joshua A; Hak, David J; Mauffrey, Cyril.
Afiliação
  • Byun SE; Denver Health Medical Center, Denver, CO, USA.
  • Vintimilla DR; Denver Health Medical Center, Denver, CO, USA.
  • Bedeir YH; University of Alexandria Medical Center, El-Hadara University Hospital, Alexandria, Egypt.
  • Dean CS; Denver Health Medical Center, Denver, CO, USA.
  • Parry JA; Denver Health Medical Center, Denver, CO, USA. joshua.parry@dhha.org.
  • Hak DJ; Hughston Clinic, Sanford, FL, USA.
  • Mauffrey C; Denver Health Medical Center, Denver, CO, USA.
Eur J Orthop Surg Traumatol ; 30(6): 1103-1107, 2020 Aug.
Article em En | MEDLINE | ID: mdl-32356122
ABSTRACT

INTRODUCTION:

Carbon-fiber-reinforced polyetheretherketone (CFR) composite plates have a more favorable stress modulus than stainless steel (SS) plates that may confer an advantage to bridge plating. The purpose of this study was to compare callus formation after CFR and SS plating of distal femur fractures.

METHODS:

A retrospective review identified distal femoral fractures treated with CFR (n = 10) and SS (n = 21) plate fixation. Callus formation was measured using the modified Radiographic Union Score for Tibia (mRUST) at 3- and 6-month follow-up by three orthopedic trauma surgeons. Loss of alignment, implant failure, and revision surgeries were reviewed.

RESULTS:

At 3 months, the mRUST in the CFR and SS groups was 9.0 (range, 6.3-12.3) and 6.9 (range, 4.3-11.7), respectively (p = 0.01). At 6 months, the mRUST in the CFR and SS groups was 11.4 (range, 7.7-16.0) and 10.5 (range, 6.0-15.7), respectively (p = 0.3). CFR and SS groups had a loss of fracture alignment in 1 (10%) and 1 (5%) patient, respectively (p = 0.5), and an unplanned revision surgery in 0 (0%) and 3 (15%) patients, respectively (p = 0.2). All three revisions surgeries in the SS group were for nonunion repair.

CONCLUSIONS:

Treatment of distal femur fractures with CFR versus SS plating resulted in greater callus formation at 3 months. At 6 months, there was no difference in callus formation between groups. A larger series of patients is necessary to determine if the observed early increased callus formation confers a benefit to clinical outcomes. LEVEL OF EVIDENCE Therapeutic level III.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Aço Inoxidável / Placas Ósseas / Calo Ósseo / Fraturas do Fêmur / Fixação Interna de Fraturas / Fibra de Carbono Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Aço Inoxidável / Placas Ósseas / Calo Ósseo / Fraturas do Fêmur / Fixação Interna de Fraturas / Fibra de Carbono Idioma: En Ano de publicação: 2020 Tipo de documento: Article