Your browser doesn't support javascript.
loading
Performance of laterally elongated pillar array columns in capillary electrochromatography mode.
Baca, Martyna; Kryj, Agata; Naghdi, Elahe; Gelin, Pierre; Sukas, Sertan; Laha, Priya; Terryn, Herman; Ottevaere, Heidi; De Malsche, Wim.
Afiliação
  • Baca M; µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
  • Kryj A; µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
  • Naghdi E; Faculty of Chemistry, Shahid Beheshti University, G.C., Tehran, Iran.
  • Gelin P; µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
  • Sukas S; µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
  • Laha P; Research Group Electrochemical and Surface Engineering (SURF), Vrije Universiteit Brussel, Brussels, Belgium.
  • Terryn H; Research Group Electrochemical and Surface Engineering (SURF), Vrije Universiteit Brussel, Brussels, Belgium.
  • Ottevaere H; Department of Applied Physics and Photonics, Vrije Universiteit Brussel, Brussels, Belgium.
  • De Malsche W; µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
Electrophoresis ; 41(15): 1287-1295, 2020 08.
Article em En | MEDLINE | ID: mdl-32358839
ABSTRACT
In the present study, cylindrical and laterally elongated pillar array columns were investigated for use in capillary electrochromatography. Minimal theoretical plate heights of H = 1.90 and 1.46 µm (in absence of sidewall effect) were obtained for coumarin C440 under unretained conditions for cylindrical and rectangular (laterally elongated, aspect ratio 4) pillar array columns, respectively. By comparing dispersion at the entire channel width to that at the central zone only, it appears that sidewall related dispersion significantly contributes to overall dispersion. A 40% reduction of the plate height was observed by taking into account only the central channel zone. A kinetic plot analysis was performed to evaluate the potential of the studied geometries by considering a maximum operating voltage of 20 kV as limiting parameter. It was demonstrated that rectangular radially elongated pillars produce a higher efficiency than cylindrical pillars and other microfabricated column structures for microchip capillary electrochromatography previously studied.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eletrocromatografia Capilar / Dispositivos Lab-On-A-Chip Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eletrocromatografia Capilar / Dispositivos Lab-On-A-Chip Idioma: En Ano de publicação: 2020 Tipo de documento: Article