Your browser doesn't support javascript.
loading
Intra-arterial computed tomography angiography with ultra-low volume of iodine contrast and stent implantation in transplant renal artery stenosis in terms of contrast-induced kidney injury - a preliminary report.
Szczurowska, Agata; Banasik, Miroslaw; Kurcz, Jacek; Mis, Marcin; Nowanska, Katarzyna; Madziarska, Katarzyna; Mazanowska, Oktawia; Krajewska, Magdalena; Garcarek, Jerzy; Guzinski, Maciej.
Afiliação
  • Szczurowska A; Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Wroclaw, Poland.
  • Banasik M; Department and Clinic of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Kurcz J; Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Wroclaw, Poland.
  • Mis M; Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Wroclaw, Poland.
  • Nowanska K; Department and Clinic of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Madziarska K; Department and Clinic of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Mazanowska O; Department and Clinic of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Krajewska M; Department and Clinic of Nephrology and Transplantation Medicine, Wroclaw Medical University, Wroclaw, Poland.
  • Garcarek J; Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Wroclaw, Poland.
  • Guzinski M; Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw Medical University, Wroclaw, Poland.
Pol J Radiol ; 85: e174-e177, 2020.
Article em En | MEDLINE | ID: mdl-32419881
ABSTRACT

PURPOSE:

Traditional digital subtraction angiography is still regarded as the gold standard in the diagnostics of transplant renal artery stenosis (TRAS). However, this procedure requires a high volume of iodine contrast medium for optimal visualisation of the renal artery. The aim of this study was to analyse both the usefulness and the safety of intra-arterial computed tomography angiography (IA-CTA) with ultra-low-volume iodine contrast administration in the diagnostic and therapeutic management of TRAS in patients with impaired renal transplant function. MATERIAL AND

METHODS:

Thirty-three patients with a suspicion of TRAS based on Doppler-ultrasound and clinical setting underwent IA-CTA with ultra-low iodine contrast volume. A special, author-elaborated CTA protocol was used. The volume of 8-18 ml of diluted iodine contrast medium was administered through a catheter with the tip placed 2 cm below the aortic bifurcation.

RESULTS:

In six patients the CTA examinations revealed TRAS in three configurations in the anastomosis, in the trunk (critical and high-grade), or in both sections. Stenoses were treated with primary stenting obtaining favourable anatomical outcome. No intervention-related complications were observed. No contrast-induced acute kidney injury was diagnosed in this study. Mean serum creatinine concentration was 2.93 ± 0.89 mg/dl at the baseline and 2.89 ± 1.73 mg/dl and 2.17 ± 0.51 mg/dl after three and seven days from IA-CTA, respectively.

CONCLUSIONS:

Intra-arterial CTA with ultra-low volume of iodine contrast seems to be a safe and reliable diagnostic tool to detect and assess TRAS in the aspect of stent implantation. Application of this imaging modality eliminates the need for a high volume of iodine contrast and thus does not adversely influence renal transplant function.