Your browser doesn't support javascript.
loading
Quantification of cylindrospermopsin, anatoxin-a and homoanatoxin-a in cyanobacterial bloom freshwater using direct injection/SPE coupled with UPLC-MS/MS.
Tran, Ngoc Han; Li, Yiwen; Reinhard, Martin; Goh, Kwan Chien; Sukarji, Nur Hanisah Binte; You, Luhua; He, Yiliang; Gin, Karina Yew-Hoong.
Afiliação
  • Tran NH; Institute of Research and Development, Duy Tan University, Da Nang 550000, Viet Nam; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower, #15-02, Singapore 138602, Singapore.
  • Li Y; Department of Environmental Science and Engineering, Sichuan University, China.
  • Reinhard M; Department of Civil and Environmental Engineering, Stanford University, CA 94305, USA.
  • Goh KC; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower, #15-02, Singapore 138602, Singapore.
  • Sukarji NHB; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower, #15-02, Singapore 138602, Singapore.
  • You L; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower, #15-02, Singapore 138602, Singapore.
  • He Y; School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
  • Gin KY; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower, #15-02, Singapore 138602, Singapore; Department of Civil and Environmental Engineering, National University of Singapore, 1 Engineering Drive 2, Singapore 117576, Singapore. Electronic address: ceegin
Sci Total Environ ; 731: 139014, 2020 Aug 20.
Article em En | MEDLINE | ID: mdl-32428751
ABSTRACT
Analytical methods based on direct injection (DI) and solid phase extraction (SPE) coupled with ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC- MS/MS) were developed for the determination of anatoxin-a (ATX-a), cylindrospermopsin (CYN), and homoanatoxin-a (HATX-a) in freshwater samples impacted with cyanobacterial blooms. The presence of CYN in freshwater samples was detected and quantified based on direct injection method, while ATX-a and HATX-a could be determined by both DI and SPE-based methods. Matrix effects (ME) on the signal intensity of the cyanotoxins were systematically evaluated for both direct injection and SPE extract samples. CYN, ATX-a, and HATX-a suffered a significant suppression during UPLC-MS/MS. The selection of internal standards (ISs) for compensating/correcting the losses of target cyanotoxins during sample preparation and matrix effects in UPLC-MS/MS analyses were systematically evaluated. Acetaminophen-d4 (an isotopically labelled acetaminophen) is a suitable internal standard for correcting the ME on the signal intensity of ATX-a and HATX-a, while the use of L-phenylalanine-d5 or caffeine-d9 as IS for correcting ME of these toxins was not efficient, as expected. The method detection limit (MDL) for the target cyanotoxins ranged from 0.6 to 15 ng/L, which is sensitive enough to detect the presence of these toxins in cyanobacterial bloom freshwater. The developed methods were successfully applied for routine monitoring of the occurrence of these cyanotoxins in a local water body. Monitoring results depicted that ATX-a, CYN and HATX-a were ubiquitously detected in water samples, at concentrations ranging from 70 to 24,600 ng/L.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Extração em Fase Sólida Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Extração em Fase Sólida Idioma: En Ano de publicação: 2020 Tipo de documento: Article