Your browser doesn't support javascript.
loading
Transluminal attenuation gradient derived from coronary CT angiography to predict ischemia in SPECT myocardial perfusion imaging: Effect of coronary cross-sectional area.
von Felten, Elia; Benz, Dominik C; Benetos, Georgios; Giannopoulos, Andreas A; Messerli, Michael; Gräni, Christoph; Fuchs, Tobias A; Gebhard, Catherine; Buechel, Ronny R; Kaufmann, Philipp A; Pazhenkottil, Aju P.
Afiliação
  • von Felten E; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Benz DC; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Benetos G; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Giannopoulos AA; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Messerli M; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Gräni C; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Fuchs TA; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Gebhard C; Department of Cardiology, University Hospital Zurich, Zurich, Switzerland.
  • Buechel RR; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Kaufmann PA; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
  • Pazhenkottil AP; Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
J Nucl Cardiol ; 29(1): 350-358, 2022 Feb.
Article em En | MEDLINE | ID: mdl-32613474
ABSTRACT

BACKGROUND:

Coronary computed tomography angiography (CCTA)-based transluminal attenuation gradient (TAG) was suggested to determine the functional significance of a stenosis. However, evidence that TAG acquired by wide-volume scanners can assess the hemodynamic significance of stenosis assessed by single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is lacking. Moreover, coronary cross-sectional area may influence TAG. Hence, we aimed at assessing the diagnostic value of TAG to predict ischemia in SPECT-MPI and the correlation between TAG and the transluminal cross-sectional area gradient (TCG).

METHODS:

Patients undergoing CCTA and SPECT-MPI for suspected coronary artery disease were included. TAG and TCG were calculated measuring the mean vessel attenuation and the cross-sectional area along major coronary vessels at 5-mm intervals.

RESULTS:

A total of 255 coronary arteries of 87 patients were included. TAG and TCG did not discriminate between coronary arteries with or without ischemia as assessed by SPECT-MPI (p = .44 and p = .25, respectively). The area under the curve to predict ischemia was not increased by adding TAG (0.88, 95% CI 0.83-0.92) or TCG (0.87, 95% CI 0.81-0.90) to CCTA alone (0.85, 95% CI 0.80-0.89). There was a significant correlation between TAG and TCG (r = 0.43; p < .001).

CONCLUSIONS:

CCTA-derived TAG and TCG do not offer any value in predicting ischemia assessed by SPECT-MPI. TAG is partly affected by differences in the coronary luminal area.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose Coronária / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose Coronária / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2022 Tipo de documento: Article