Your browser doesn't support javascript.
loading
Valve-in-Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve-in-Valve for Degenerated Surgical Aortic Bioprostheses: A 3-Center Comparison of Hemodynamic and 1-Year Outcome.
Raschpichler, Matthias C; Woitek, Felix; Chakravarty, Tarun; Flint, Nir; Yoon, Sung-Han; Mangner, Norman; Patel, Chinar G; Singh, Chetana; Kashif, Mohammad; Kiefer, Philip; Holzhey, David; Linke, Axel; Stachel, Georg; Thiele, Holger; Borger, Michael A; Makkar, Raj R.
Afiliação
  • Raschpichler MC; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Woitek F; University Clinic of Cardiac Surgery Heart Center Leipzig Leipzig Germany.
  • Chakravarty T; Department of Cardiology Dresden University Hospital Dresden Germany.
  • Flint N; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Yoon SH; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Mangner N; Department of Cardiology Tel-Aviv Sourasky Medical Center Sackler Faculty of Medicine Tel-Aviv University Tel-Aviv Israel.
  • Patel CG; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Singh C; Department of Cardiology Dresden University Hospital Dresden Germany.
  • Kashif M; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Kiefer P; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Holzhey D; Cedars-Sinai Smidt Heart Institute Los Angeles CA.
  • Linke A; University Clinic of Cardiac Surgery Heart Center Leipzig Leipzig Germany.
  • Stachel G; University Clinic of Cardiac Surgery Heart Center Leipzig Leipzig Germany.
  • Thiele H; Department of Cardiology Dresden University Hospital Dresden Germany.
  • Borger MA; Department of Internal Medicine/Cardiology Heart Center Leipzig at University of Leipzig Germany.
  • Makkar RR; Department of Internal Medicine/Cardiology Heart Center Leipzig at University of Leipzig Germany.
J Am Heart Assoc ; 9(14): e013973, 2020 07 21.
Article em En | MEDLINE | ID: mdl-32646262
ABSTRACT
Background As transcatheter aortic valve replacement (TAVR) is expected to progress into younger patient populations, valve-in-TAVR (ViTAVR) may become a frequent consideration. Data on ViTAVR, however, are limited. This study investigated the outcome of ViTAVR in comparison to valve in surgical aortic valve replacement (ViSAVR), because ViSAVR is an established procedure for higher-risk patients requiring repeated aortic valve intervention. Methods and Results Clinical and procedural data of patients who underwent ViTAVR at 3 sites in the United States and Germany were retrospectively compared with data of patients who underwent ViSAVR at Cedars-Sinai Medical Center, according to Valve Academic Research Consortium-2 criteria. A total of 99 consecutive patients, 52.5% women, with a median Society of Thoracic Surgeons score of 7.2 were identified. Seventy-four patients (74.7%) underwent ViSAVR, and 25 patients (25.3%) underwent ViTAVR. Balloon-expandable devices were used in 72.7%. ViSAVR patients presented with smaller index devices (21.0 versus 26.0 mm median true internal diameter; P<0.001). Significantly better postprocedural hemodynamics (median prosthesis mean gradient, 12.5 [interquartile range, 8.8-16.2] versus 16.0 [interquartile range, 13.0-20.5] mm Hg; P=0.045) were observed for ViTAVR compared with the ViSAVR. Device success, however, was not different (79.2% and 66.2% for ViTAVR and ViSAVR, respectively; P=0.35), as were rates of permanent pacemaker implantation (16.7% versus 5.4%; P=0.1). One-year-mortality was 9.4% and 13.4% for ViTAVR and ViSAVR, respectively (log-rank P=0.38). Conclusions Compared with ViSAVR, ViTAVR provides acceptable outcomes, with slightly better hemodynamics, similar device success rates, and similar 1-year mortality.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Reoperação / Bioprótese / Falha de Prótese / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Reoperação / Bioprótese / Falha de Prótese / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2020 Tipo de documento: Article