Cardiopulmonary coupling-derived sleep quality is associated with improvements in blood pressure in patients with obstructive sleep apnea at high-cardiovascular risk.
Magnusdottir, Solveig; Hilmisson, Hugi; Thomas, Robert J.
Afiliação
  • Magnusdottir S; MyCardio LLC, SleepImage, Denver, Colorado.
  • Hilmisson H; MyCardio LLC, SleepImage, Denver, Colorado.
  • Thomas RJ; Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
J Hypertens ; 38(11): 2287-2294, 2020 11.
Article em En | MEDLINE | ID: mdl-32649638
OBJECTIVE: Investigate if changes in objective sleep quality index (SQI) assessed through cardiopulmonary-coupling analysis impacts blood pressure (BP) in patients with obstructive sleep apnea at high-cardiovascular risk. METHODS: Secondary analysis of ECG and pulse-oximetry-[oxygen saturation (SpO2)] data from the Heart Biomarker Evaluation in Apnea Treatment study, multicenter, controlled trial in patients with cardiovascular disease and moderate-severe obstructive sleep apnea, randomly assigned to intervention of healthy lifestyle and sleep hygiene education (HLSE; control group), continuous positive airway pressure (CPAP) or nocturnal supplemental oxygen (NSO). Participants with good-quality ECG-signal and SpO2-signal (n = 241) were included. RESULTS: CPAP-therapy significantly improved BP, with net average improvement in mean arterial blood pressure during sleep (MAP) when compared with nocturnal supplemental oxygen-therapy or healthy lifestyle and sleep education-therapy, -3.92 (P = 0.012) and -3.83 (P = 0.016), respectively. When stratified on the basis of baseline-SQI, CPAP-therapy improves 24-h MAP -3.02 (P = 0.030) and MAP -5.00 (P = 0.001), in patients with compromised baseline-SQI (SQI < 55). Stratifying the cohort based on changes in SQI during the study period (SQI-SQI), controlling for sex, age over 60, apnea-hypopnea index, SpO2 less than 80%, baseline BP and cardiovascular disease, significant differences are observed comparing the groups that Improved-SQI (SQI < 55, SQI ≥ 55) and Declined-SQI (SQI ≥ 55, SQI < 55) in MAP -4.87 (P = 0.046) and mean diastolic blood pressure (MDP) -4.42 (P = 0.026) as well as MAP -6.36 (P = 0.015), mean systolic blood pressure wake (MSP) -7.80 (P = 0.048) and MDP -5.64 (P = 0.009), respectively. Improved SQI reflects the magnitude of positive effect on BP which is reached mostly through initiation of CPAP-therapy. CONCLUSION: Cardiopulmonary coupling-derived sleep quality impacted 24-h MAP and MDP, as well as BP during wake, in patients participating in the Heart Biomarker Evaluation in Apnea Treatment-study.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sono / Pressão Sanguínea / Doenças Cardiovasculares / Apneia Obstrutiva do Sono Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sono / Pressão Sanguínea / Doenças Cardiovasculares / Apneia Obstrutiva do Sono Idioma: En Ano de publicação: 2020 Tipo de documento: Article