Your browser doesn't support javascript.
loading
Evaluation of the characteristics of the neutron beam of a linac-based neutron source for boron neutron capture therapy.
Kumada, Hiroaki; Takada, Kenta; Tanaka, Susumu; Matsumoto, Yoshitaka; Naito, Fujio; Kurihara, Toshikazu; Sugimura, Takashi; Sato, Masaharu; Matsumura, Akira; Sakurai, Hideyuki; Sakae, Takeji.
Afiliação
  • Kumada H; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan. Electronic address: kumada@pmrc.tsukuba.ac.jp.
  • Takada K; Gunma Prefectural College of Health Sciences, 323-1, Kamiokimachi, Maebashi, 317-0052, Japan.
  • Tanaka S; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
  • Matsumoto Y; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
  • Naito F; High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan.
  • Kurihara T; High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan.
  • Sugimura T; High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan.
  • Sato M; High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan.
  • Matsumura A; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
  • Sakurai H; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
  • Sakae T; Faculty of Medicine, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
Appl Radiat Isot ; 165: 109246, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32692654
ABSTRACT
The linac-base neutron source "iBNCT" developed by the Tsukuba team has begun to generate a large intensity of neutrons. To confirm the applicability of the device to BNCT, several characteristic measurements have been implemented. In a water phantom experiment, when the accelerator was operated with an average current of 1.4 mA, the maximum thermal neutron flux was approximately 7.8 × 108 (n/cm2/s). Results demonstrate the stability of the linac over time, showing its promising potential for future patient treatment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Nêutrons Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Nêutrons Idioma: En Ano de publicação: 2020 Tipo de documento: Article