Your browser doesn't support javascript.
loading
Optimal 99mTc activity ratio in the single-day stress-rest myocardial perfusion imaging protocol: A multi-SPECT phantom study.
Zoccarato, Orazio; Matheoud, Roberta; Lecchi, Michela; Scabbio, Camilla; Claudio, Marcassa; Brambilla, Marco.
Afiliação
  • Zoccarato O; Department of Nuclear Medicine, S. Maugeri Foundation, IRCCS, Scientific Institute of Veruno (NO), Veruno, Italy.
  • Matheoud R; Department of Medical Physics, University Hospital 'Maggiore della Carità', Novara, Italy.
  • Lecchi M; Health Physics Unit, ASST Santi Paolo e Carlo, Milan, Italy.
  • Scabbio C; Health Physics Unit, ASST Santi Paolo e Carlo, Milan, Italy.
  • Claudio M; Department of Cardiology, S. Maugeri Foundation, IRCCS, Scientific Institute of Veruno (NO), Veruno, Italy.
  • Brambilla M; Department of Medical Physics, University Hospital 'Maggiore della Carità', Novara, Italy. marco.brambilla@maggioreosp.novara.it.
J Nucl Cardiol ; 28(1): 338-349, 2021 02.
Article em En | MEDLINE | ID: mdl-32720060
BACKGROUND: This investigation used image data generated by an anthropomorphic phantom to determine the minimal 99mTc rest-stress activity concentration ratio (R) able to minimize the ghosting effect in the single-day stress-first myocardial perfusion imaging, using different positions of the perfusion defect (PD), scanners and reconstruction protocols. METHODS: A cardiac phantom with a simulated PD was imaged under different R using different gamma cameras and reconstruction algorithms. The residual activity from precedent stress administration was simulated by modeling effective half-times in each compartment of the phantom and assuming a delay of 3 hours between the stress and rest studies. The net contrast (NC) of the PD in the rest study was assessed for different R, PD positions and scanner/software combinations. The optimal R will be the one that minimize the NC in the rest images RESULTS: The activity concentration ratio R, the position of the PD and the scanner/software combinations were all main effects with a statistically significant impact on the NC, in decreasing order of relevance. The NC diminished significantly only for R values up to 2. No further improvement was observed for NC for R values above 2 and up to 3. NC was significantly higher in anteroseptal than in posterolateral positions of the PD and higher for solid-state cameras. CONCLUSIONS: A rest-stress activity concentration ratio R of 2 in single-day stress-first myocardial perfusion imaging is enough to achieve the maximum net contrast in the PD. This ratio should be used to optimize patient's radiation exposure.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Isquemia Miocárdica / Imagens de Fantasmas / Compostos Radiofarmacêuticos / Imagem de Perfusão do Miocárdio Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Isquemia Miocárdica / Imagens de Fantasmas / Compostos Radiofarmacêuticos / Imagem de Perfusão do Miocárdio Idioma: En Ano de publicação: 2021 Tipo de documento: Article