Hybrid pixel direct detector for electron energy loss spectroscopy.
Plotkin-Swing, Benjamin; Corbin, George J; De Carlo, Sacha; Dellby, Niklas; Hoermann, Christoph; Hoffman, Matthew V; Lovejoy, Tracy C; Meyer, Chris E; Mittelberger, Andreas; Pantelic, Radosav; Piazza, Luca; Krivanek, Ondrej L.
Afiliação
  • Plotkin-Swing B; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA. Electronic address: plotkin-swing@nion.com.
  • Corbin GJ; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • De Carlo S; DECTRIS Ltd., Taefernweg 1, 5405 Baden-Daettwil, Switzerland.
  • Dellby N; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • Hoermann C; DECTRIS Ltd., Taefernweg 1, 5405 Baden-Daettwil, Switzerland.
  • Hoffman MV; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • Lovejoy TC; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • Meyer CE; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • Mittelberger A; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA.
  • Pantelic R; DECTRIS Ltd., Taefernweg 1, 5405 Baden-Daettwil, Switzerland.
  • Piazza L; DECTRIS Ltd., Taefernweg 1, 5405 Baden-Daettwil, Switzerland.
  • Krivanek OL; Nion Co., 11511 NE 118th St., Kirkland, WA 98034, USA; Department of Physics, Arizona State University, Tempe, AZ 85287, USA.
Ultramicroscopy ; 217: 113067, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32801089
ABSTRACT
We characterize a hybrid pixel direct detector and demonstrate its suitability for electron energy loss spectroscopy (EELS). The detector has a large dynamic range, narrow point spread function, detective quantum efficiency ≥ 0.8 even without single electron arrival discrimination, and it is resilient to radiation damage. It is capable of detecting ~5 × 106 electrons/pixel/second, allowing it to accommodate up to 0.8 pA per pixel and hence >100 pA EELS zero-loss peak (ZLP) without saturation, if the ZLP is spread over >125 pixels (in the non-dispersion direction). At the same time, it can reliably detect isolated single electrons in the high loss region of the spectrum. The detector uses a selectable threshold to exclude low energy events, and this results in essentially zero dark current and readout noise. Its maximum frame readout rate at 16-bit digitization is 2250 full frames per second, allowing for fast spectrum imaging. We show applications including EELS of boron nitride in which an unsaturated zero loss peak is recorded at the same time as inner shell loss edges, elemental mapping of an STO/BTO/LMSO multilayer, and efficient parallel acquisition of angle-resolved EEL spectra (S(q, ω)) of boron nitride.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article