Your browser doesn't support javascript.
loading
A liquid chromatography-high resolution mass spectrometry method for the determination of thirty-three per- and polyfluoroalkyl substances in animal liver.
Barola, Carolina; Moretti, Simone; Giusepponi, Danilo; Paoletti, Fabiola; Saluti, Giorgio; Cruciani, Gabriele; Brambilla, Gianfranco; Galarini, Roberta.
Afiliação
  • Barola C; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy.
  • Moretti S; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy.
  • Giusepponi D; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy.
  • Paoletti F; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy.
  • Saluti G; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy.
  • Cruciani G; Department of Chemistry, Biology and Biotechnology, University of Perugia, via Elce di Sotto, 8 - 06123 Perugia, Italy.
  • Brambilla G; Istituto Superiore di Sanità, Viale Regina Elena, 299, 00161 - Rome, Italy.
  • Galarini R; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 - Perugia, Italy. Electronic address: r.galarini@izsum.it.
J Chromatogr A ; 1628: 461442, 2020 Sep 27.
Article em En | MEDLINE | ID: mdl-32822981
ABSTRACT
An analytical method for the quantification of thirty-three perfluoroalkyl and polyfluoroalkyl substances (PFASs) in animal liver was developed applying the isotopic dilution methodology with twenty-one labelled isotopologues of native compounds. The proposed protocol involved the determination of short and long aliphatic chain PFASs (C4C18) extracting liver with acetonitrile followed by two clean-up steps. The instrumental analysis was performed with liquid chromatography coupled to high-resolution mass spectrometry. The acquisition method combined full MS/dd-MS2, t-SIM/dd-MS2 and SIM experiments with variable resolution in order to maximize in one chromatographic run accuracy, sensitivity and selectivity. An eight-level validation study was performed evaluating linearity, trueness, precision, quantification and detection limits. Trueness was from 94 to 126% with intra-laboratory reproducibility lower than 20%. Limits of quantification were in the range 2-100 pg g-1, except for 2,3,3,3-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoic acid, HFPO-DA (500 pg g-1). The analysis of a certified reference material (IRMM-427) and participation in a proficiency test scheme (FAPAS - 0687) confirmed these satisfactory performances. Finally, the application of the developed procedure to detect PFASs in sixteen liver samples of farm animals revealed that chicken was the less contaminated species.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Química Analítica / Cromatografia Líquida de Alta Pressão / Cromatografia Líquida / Espectrometria de Massas em Tandem / Fluorocarbonos / Fígado Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas de Química Analítica / Cromatografia Líquida de Alta Pressão / Cromatografia Líquida / Espectrometria de Massas em Tandem / Fluorocarbonos / Fígado Idioma: En Ano de publicação: 2020 Tipo de documento: Article