Your browser doesn't support javascript.
loading
A graphene oxide-molybdenum disulfide composite used as stationary phase for determination of sulfonamides in open-tubular capillary electrochromatography.
Cai, Zhimin; Hu, Xiaoyu; Zong, Rui; Wu, Hanqing; Jin, Xiaotong; Yin, Han; Huang, Chuanlin; Xiang, Yuhong; Ye, Nengsheng.
Afiliação
  • Cai Z; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Hu X; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Zong R; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Wu H; College of Teacher Education, Capital Normal University, Beijing, 100048, PR China. Electronic address: wuhanqing1981@aliyun.com.
  • Jin X; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Yin H; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Huang C; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Xiang Y; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China.
  • Ye N; Department of Chemistry, Capital Normal University, Beijing, 100048, PR China. Electronic address: yensh@cnu.edu.cn.
J Chromatogr A ; 1629: 461487, 2020 Oct 11.
Article em En | MEDLINE | ID: mdl-32823013
ABSTRACT
A graphene oxide-molybdenum disulfide (GO-MoS2) composite was synthesized and utilized as the highly efficient stationary phase of open-tubular capillary electrochromatography (OT-CEC). The characterization results indicated that GO-MoS2 composite was successfully synthesized. The GO-MoS2-coated capillary column was prepared by covalent immobilization method for the determination of seven sulfonamides. The baseline separation of seven sulfonamides was achieved by GO-MoS2-coated capillary column. The linear range was 0.05-100 µg/mL for sulfisomidine, sulfathiazole, sulfamerazine, phthalylsulfathiazole and sulfacetamide, 0.1-100 µg/mL for sulfamonomethoxine and sulfachloropyridazine with a satisfactory correlation coefficients (R2) > 0.9994. This developed OT-CEC method was successfully applied to determinate of seven sulfonamides in environmental water and milk samples with good recoveries of 85.77% - 109.10% and 80.03% - 109.97%, respectively. These results indicated that GO-MoS2-coated capillary column possessed good stability and repeatability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfonamidas / Dissulfetos / Eletrocromatografia Capilar / Grafite / Molibdênio Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfonamidas / Dissulfetos / Eletrocromatografia Capilar / Grafite / Molibdênio Idioma: En Ano de publicação: 2020 Tipo de documento: Article