Your browser doesn't support javascript.
loading
Paper-based Chemiluminescence Device with Co-Fe Nanocubes for Sensitive Detection of Caffeic Acid.
Zhang, Liu; Hou, Yue; Guo, Xiaoyan; Liu, Wei; Lv, Congcong; Peng, Xing; Zhang, Zixuan.
Afiliação
  • Zhang L; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
  • Hou Y; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
  • Guo X; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
  • Liu W; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China. weiliu@126.com.
  • Lv C; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
  • Peng X; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
  • Zhang Z; Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, China.
Anal Sci ; 37(2): 293-299, 2021 Feb 10.
Article em En | MEDLINE | ID: mdl-32863334
ABSTRACT
In this work, a new chemiluminescence (CL) system of Co-Fe prussian blue analogs nanocubes (Co-Fe PBA NCs) that can catalyze luminol to produce strong CL in the absence of H2O2 was established. Co-Fe PBA NCs have the property of oxidase-like activity, and it can catalyze the generation of active oxygen radicals in a dissolved oxygen system. Since caffeic acid (CA) can remove reactive oxygen species in the system, a sensitive detection method for CA on a paper-based chip was developed. Under the optimal conditions, this method showed a good linear response to CA in the range of 10 - 800 ng mL-1 with a limit of 3 ng mL-1. The proposed method had been used for the determination of CA in tea samples. The results may open a new avenue for the catalytic property on luminol CL system without extra oxidants.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Papel / Ácidos Cafeicos / Cobalto / Nanoestruturas / Ferrocianetos / Ferro Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Papel / Ácidos Cafeicos / Cobalto / Nanoestruturas / Ferrocianetos / Ferro Idioma: En Ano de publicação: 2021 Tipo de documento: Article