Your browser doesn't support javascript.
loading
Azimuthal-rotation sample holder for molecular orientation analysis.
Harano, Takayuki; Takeichi, Yasuo; Ohigashi, Takuji; Shindo, Daisuke; Nemoto, Eiji; Wakabayashi, Daisuke; Yamashita, Shohei; Murao, Reiko; Kimura, Masao.
Afiliação
  • Harano T; Advanced Technology Research Laboratories, Research and Development, Nippon Steel Corporation, 20-1 Shintomi, Futtsu, Chiba 293-8511, Japan.
  • Takeichi Y; Department of Materials Structure Science, School of High Energy Accelerator Science, The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan.
  • Ohigashi T; UVSOR Synchrotron Facility, Institute for Molecular Science, 38 Nishigonaka, Myodaiji, Okazaki, Aichi 444-8585, Japan.
  • Shindo D; Kohzu Precision Co. Ltd, 2-6-15 Kurigi, Asao, Kawasaki, Kanagawa 215-8521, Japan.
  • Nemoto E; Kohzu Precision Co. Ltd, 2-6-15 Kurigi, Asao, Kawasaki, Kanagawa 215-8521, Japan.
  • Wakabayashi D; Department of Materials Structure Science, School of High Energy Accelerator Science, The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan.
  • Yamashita S; Department of Materials Structure Science, School of High Energy Accelerator Science, The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan.
  • Murao R; Advanced Technology Research Laboratories, Research and Development, Nippon Steel Corporation, 20-1 Shintomi, Futtsu, Chiba 293-8511, Japan.
  • Kimura M; Department of Materials Structure Science, School of High Energy Accelerator Science, The Graduate University for Advanced Studies (SOKENDAI), 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan.
J Synchrotron Radiat ; 27(Pt 5): 1167-1171, 2020 Sep 01.
Article em En | MEDLINE | ID: mdl-32876590
In this study, an azimuthal-rotation sample holder compatible with scanning transmission X-ray microscopy was developed. This holder exhibits improvement in the accuracy of rotation angles and reduces the displacement of the rotation axes during azimuthal rotation by using a crossed roller bearing. To evaluate the performance of the holder, the authors investigated the dependence of the optical density around the C K-edge absorption of π-orbital-oriented domains in natural spherical graphite on the rotational angle by using linearly horizontally and vertically polarized undulator radiation. Based on the dependence of the optical density ratio between C 1s → π* and 1s → σ* excitation on the polarization angle of the X-rays, the average two-dimensional orientation angle of the π orbital in each position in a natural spherical graphite sample was visualized.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article