A Cyclotron Decommissioning Radiological Assessment Exercise Performed by Student Mentees Underrepresented in the Radiation Safety Profession.
Zapata, Jessie R; Stewart, Justice; Kelly, Kalifa O; Taylor, Aaron R; Martinez, Erika I; Amoako, Kofi; Gutierrez, Janet M; Emery, Robert J; Cheng, Sai Yan; Patlovich, Scott J; Harvey, Mark C.
Afiliação
  • Zapata JR; Department of Physics, Texas Southern University, Houston, TX 77004.
  • Stewart J; Department of Physics, Texas Southern University, Houston, TX 77004.
  • Kelly KO; Department of Chemistry, Texas Southern University, Houston, TX 77004.
  • Amoako K; Department of Physics, Texas Southern University, Houston, TX 77004.
  • Gutierrez JM; Safety, Health, Environment & Risk Management, The University of Texas Health Science Center at Houston, TX 77054.
  • Emery RJ; Safety, Health, Environment & Risk Management, The University of Texas Health Science Center at Houston, TX 77054.
  • Cheng SY; Safety, Health, Environment & Risk Management, The University of Texas Health Science Center at Houston, TX 77054.
  • Patlovich SJ; Safety, Health, Environment & Risk Management, The University of Texas Health Science Center at Houston, TX 77054.
  • Harvey MC; Department of Physics, Texas Southern University, Houston, TX 77004.
Health Phys ; 120(1): 105-111, 2021 01.
Article em En | MEDLINE | ID: mdl-32897987
ABSTRACT
Cyclotrons used in nuclear medicine imaging accelerate protons, deuterons, and helium ions to bombard a target, which produces nuclear reactions that generate positron-emitting radionuclides. Secondary neutrons are nonuniformly emitted in these reactions and induce heterogeneous activation of the cyclotron components and concrete vault enclosure. This poses radioactive waste management complications when decommissioning a cyclotron facility, since the objective is to ensure that exposures are within regulatory limits and as low as reasonably achievable (ALARA). The McGovern Medical School in The University of Texas Health Science Center in Houston housed a Scanditronix MC40 cyclotron that produced short-lived radioisotopes for Positron Emission Tomography (PET) imaging from 1984 to 2001 until Tropical Storm Allison rendered it inoperable. The purpose of this study was to provide underrepresented Science, Technology, Engineering and Mathematics (STEM) students an ALARA experience with a practical problem encountered in the radiation safety profession. Gamma dose rate measurements were performed with both a Mirion InSpector 1000 spectrometer and Fluke 451P survey meter in the vault at locations identified as hotspots based on preliminary scoping surveys with the Ludlum model 44-9 detector. However, gamma spectra were measured with the spectrometer exclusively at hotspots along the west wall. Results indicated the maximum gamma dose rate of 129 ± 31 nSv h was about 2 times background near the central beam transport line of the now inoperable cyclotron. Furthermore, gamma emission peaks were identified in the spectra from trace amounts of Co and Eu in the vault's concrete walls.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Ciclotrons / Medicina Nuclear Idioma: En Ano de publicação: 2021 Tipo de documento: Article