Your browser doesn't support javascript.
loading
Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid and Accurate Confirmatory Diagnosis of HTLV-1/2 Infection.
Gomes, Yago; Caterino-de-Araujo, Adele; Campos, Karoline; Gonçalves, Maria Gisele; Leite, Ana Claudia; Lima, Marco Antonio; Araújo, Abelardo; Silva, Marcus Tulius; Espíndola, Otávio.
Afiliação
  • Gomes Y; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
  • Caterino-de-Araujo A; Laboratory of HTLV Research, Immunology Center, Adolfo Lutz Institute, São Paulo 01246-000, Brazil.
  • Campos K; Laboratory of HTLV Research, Immunology Center, Adolfo Lutz Institute, São Paulo 01246-000, Brazil.
  • Gonçalves MG; Laboratory of HTLV Research, Immunology Center, Adolfo Lutz Institute, São Paulo 01246-000, Brazil.
  • Leite AC; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
  • Lima MA; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
  • Araújo A; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
  • Silva MT; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
  • Espíndola O; Laboratory for Clinical Research in Neuroinfections, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil.
Viruses ; 12(9)2020 09 04.
Article em En | MEDLINE | ID: mdl-32899621
ABSTRACT
Laboratory diagnosis of human T-lymphotropic viruses (HTLV) 1 and 2 infection is performed by serological screening and further confirmation with serological or molecular assays. Thus, we developed a loop-mediated isothermal nucleic acid amplification (LAMP) assay for the detection of HTLV-1/2 in blood samples. The sensitivity and accuracy of HTLV-1/2 LAMP were defined with DNA samples from individuals infected with HTLV-1 (n = 125), HTLV-2 (n = 19), and coinfected with HIV (n = 82), and compared with real-time polymerase chain reaction (qPCR) and PCR-restriction fragment length polymorphism (RFLP). The overall accuracy of HTLV-1/2 LAMP (95% CI 74.8-85.5%) was slightly superior to qPCR (95% CI 69.5-81.1%) and similar to PCR-RFLP (95% CI 79.5-89.3%). The sensitivity of LAMP was greater for HTLV-1 (95% CI 83.2-93.4%) than for HTLV-2 (95% CI 43.2-70.8%). This was also observed in qPCR and PCR-RFLP, which was associated with the commonly lower HTLV-2 proviral load. All molecular assays tested showed better results with samples from HTLV-1/2 mono-infected individuals compared with HIV-coinfected patients, who present lower CD4 T-cell counts. In conclusion, HTLV-1/2 LAMP had similar to superior performance than PCR-based assays, and therefore may represent an attractive alternative for HTLV-1/2 diagnosis due to reduced working time and costs, and the simple infrastructure needed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus Linfotrópico T Tipo 1 Humano / Infecções por HTLV-I / Vírus Linfotrópico T Tipo 2 Humano / Infecções por HTLV-II / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus Linfotrópico T Tipo 1 Humano / Infecções por HTLV-I / Vírus Linfotrópico T Tipo 2 Humano / Infecções por HTLV-II / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular Idioma: En Ano de publicação: 2020 Tipo de documento: Article