Your browser doesn't support javascript.
loading
Validation and Precision of Mixed Reality Technology in Baha Attract Implant Surgery.
Tian, Xu; Gao, Zhi-Qiang; Zhang, Zhu-Hua; Chen, Yu; Zhao, Yang; Feng, Guo-Dong.
Afiliação
  • Tian X; Department of Otolaryngology.
  • Gao ZQ; Department of Otolaryngology.
  • Zhang ZH; Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College Dongcheng District, Beijing, China.
  • Chen Y; Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College Dongcheng District, Beijing, China.
  • Zhao Y; Department of Otolaryngology.
  • Feng GD; Department of Otolaryngology.
Otol Neurotol ; 41(9): 1280-1287, 2020 10.
Article em En | MEDLINE | ID: mdl-32925861
OBJECTIVE: To test the feasibility of image-guided Baha Attract implant surgery with mixed reality (MR) in the form of the HoloLens to visualize critical structures and facilitate precise Baha implant placement. METHODS: A cadaveric case study of bilateral Baha Attract implant approaches was conducted using Star Atlas MR three-dimensional (3D) medical interaction system guidance at the Otolaryngology Department of PUMCH, Beijing, China. The accuracy of visual surface registration was determined by the target registration error (TRE) between the predefined points on the preoperative 3D holographic Baha Attract implant model and the postoperatively reconstructed 3D model. RESULTS: Bilateral Baha Attract implantation was completed successfully for all four cadaveric heads using the Star Atlas MR 3D medical interaction system with the HoloLens. The preoperative 3D digital model characteristics (including bone quality and thickness and avoidance of cranial vessels, air cells, and cranial sutures) corresponded well with the 3D model of the actual implantation reconstructed postoperatively. The median TRE of our system was 2.97 mm (ranging from 1.98 to 4.58 mm) in terms of distance and 2.76 degrees (ranging from 0.59 to 6.4 degrees) in terms of angle. CONCLUSIONS: Applying MR technology in the form of the HoloLens in Baha Attract implant surgery is feasible and could improve the accuracy of the surgery. The described MR system for Baha Attract implantation has the potential to improve the surgeon's confidence, as well as the surgical safety, efficiency, and precision.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Realidade Aumentada Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Realidade Aumentada Idioma: En Ano de publicação: 2020 Tipo de documento: Article