Your browser doesn't support javascript.
loading
Effect of low-frequency electric field screening on motility of human sperm.
Górski, Romuald; Kotwicka, Malgorzata; Skibinska, Izabela; Jendraszak, Magdalena; Wosinski, Stanislaw.
Afiliação
  • Górski R; University of Life Sciences, Poznan, Poland.
  • Kotwicka M; University of Medical Sciences, Poznan, Poland.
  • Skibinska I; University of Medical Sciences, Poznan, Poland.
  • Jendraszak M; University of Medical Sciences, Poznan, Poland.
  • Wosinski S; ADR Technology, Gdansk, Poland.
Ann Agric Environ Med ; 27(3): 427-434, 2020 Sep 11.
Article em En | MEDLINE | ID: mdl-32955226
ABSTRACT

INTRODUCTION:

The human body is constantly exposed to an extremely low electromagnetic field (ELF-EMF), in particular at 50 Hz, emitted by power lines, domestic distribution lines, electrical appliances, etc. It is assumed that the increase in electromagnetic exposure may cause adverse effects upon human health, as well as raising concerns regarding the impact on human fertility.

OBJECTIVE:

The aim of this in vitro study was to investigate the influence of ELF-EMF with a frequency of 50 Hz on the motility of human sperm. At the same time, the effectiveness of the dielectric screen constructed by ADR Technology ® in absorbing the emitted radiation was examined. MATERIAL AND

METHODS:

Semen samples of 20 patients were exposed to the influence of an extremely low electromagnetic field. After 5, 15 and 30 min., spermatozoa motility was analysed using a computer-assisted spermatozoa motility analysis system. The following sperm motility parameters were examined 1) velocity straight linear motility; 2) cross-beat frequency; 3) lateral head displacement; 4) homogeneity of progressive motility velocity.

RESULTS:

It was found that the ELF-EMF presented a negative effect on the motility of human spermatozoa. A significant decrease in spermatozoa motility speed and a significant increase in lateral head deviation values were observed under the influence of the electromagnetic field. ELF-EMF did not show an effect on either lateral head displacement or homogeneity of progressive motility velocity.

CONCLUSIONS:

A positive effect of the dielectric screen ADR Technology® was found. This effect compensated spermatozoa motility changes induced with ELF-EMF.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Motilidade dos Espermatozoides / Espermatozoides / Campos Eletromagnéticos Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Motilidade dos Espermatozoides / Espermatozoides / Campos Eletromagnéticos Idioma: En Ano de publicação: 2020 Tipo de documento: Article