Your browser doesn't support javascript.
loading
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions.
Lohse, S; Berrocal, J; Böhland, S; van de Laar, J; Block, M; Chenmarev, S; Düllmann, Ch E; Nagy, Sz; Ramírez, J G; Rodríguez, D.
Afiliação
  • Lohse S; Department Chemie - Standort TRIGA, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
  • Berrocal J; Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain.
  • Böhland S; Department Chemie - Standort TRIGA, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
  • van de Laar J; Department Chemie - Standort TRIGA, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
  • Block M; Department Chemie - Standort TRIGA, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
  • Chenmarev S; Helmholtz-Institut Mainz, 55099 Mainz, Germany.
  • Düllmann CE; Department Chemie - Standort TRIGA, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
  • Nagy S; Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.
  • Ramírez JG; Seven Solutions S.L., 18014 Granada, Spain.
  • Rodríguez D; Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain.
Rev Sci Instrum ; 91(9): 093202, 2020 Sep 01.
Article em En | MEDLINE | ID: mdl-33003790
ABSTRACT
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10-7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion-ion interaction between the simultaneously trapped ions (≈100) and will decrease to a negligible level once we reach single-ion sensitivity. The compactness of such a crystal makes this approach promising for direct Penning-trap mass measurements on heavy and superheavy elements.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article