Real-Life Gait Performance as a Digital Biomarker for Motor Fluctuations: The Parkinson@Home Validation Study.
Evers, Luc Jw; Raykov, Yordan P; Krijthe, Jesse H; Silva de Lima, Ana Lígia; Badawy, Reham; Claes, Kasper; Heskes, Tom M; Little, Max A; Meinders, Marjan J; Bloem, Bastiaan R.
Afiliação
  • Evers LJ; Center of Expertise for Parkinson and Movement Disorders, department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, Netherlands.
  • Raykov YP; Institute for Computing and Information Sciences, Radboud University, Nijmegen, Netherlands.
  • Krijthe JH; Department of Mathematics, School of Engineering and Applied Sciences, Aston University, Birmingham, United Kingdom.
  • Silva de Lima AL; Institute for Computing and Information Sciences, Radboud University, Nijmegen, Netherlands.
  • Badawy R; Center of Expertise for Parkinson and Movement Disorders, department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, Nijmegen, Netherlands.
  • Claes K; School of Computer Science, University of Birmingham, Birmingham, United Kingdom.
  • Heskes TM; UCB Pharma, Brussels, Belgium.
  • Little MA; Institute for Computing and Information Sciences, Radboud University, Nijmegen, Netherlands.
  • Meinders MJ; School of Computer Science, University of Birmingham, Birmingham, United Kingdom.
  • Bloem BR; Scientific Center for Quality of Healthcare (IQ healthcare), Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands.
J Med Internet Res ; 22(10): e19068, 2020 10 09.
Article em En | MEDLINE | ID: mdl-33034562
ABSTRACT

BACKGROUND:

Wearable sensors have been used successfully to characterize bradykinetic gait in patients with Parkinson disease (PD), but most studies to date have been conducted in highly controlled laboratory environments.

OBJECTIVE:

This paper aims to assess whether sensor-based analysis of real-life gait can be used to objectively and remotely monitor motor fluctuations in PD.

METHODS:

The Parkinson@Home validation study provides a new reference data set for the development of digital biomarkers to monitor persons with PD in daily life. Specifically, a group of 25 patients with PD with motor fluctuations and 25 age-matched controls performed unscripted daily activities in and around their homes for at least one hour while being recorded on video. Patients with PD did this twice once after overnight withdrawal of dopaminergic medication and again 1 hour after medication intake. Participants wore sensors on both wrists and ankles, on the lower back, and in the front pants pocket, capturing movement and contextual data. Gait segments of 25 seconds were extracted from accelerometer signals based on manual video annotations. The power spectral density of each segment and device was estimated using Welch's method, from which the total power in the 0.5- to 10-Hz band, width of the dominant frequency, and cadence were derived. The ability to discriminate between before and after medication intake and between patients with PD and controls was evaluated using leave-one-subject-out nested cross-validation.

RESULTS:

From 18 patients with PD (11 men; median age 65 years) and 24 controls (13 men; median age 68 years), ≥10 gait segments were available. Using logistic LASSO (least absolute shrinkage and selection operator) regression, we classified whether the unscripted gait segments occurred before or after medication intake, with mean area under the receiver operator curves (AUCs) varying between 0.70 (ankle of least affected side, 95% CI 0.60-0.81) and 0.82 (ankle of most affected side, 95% CI 0.72-0.92) across sensor locations. Combining all sensor locations did not significantly improve classification (AUC 0.84, 95% CI 0.75-0.93). Of all signal properties, the total power in the 0.5- to 10-Hz band was most responsive to dopaminergic medication. Discriminating between patients with PD and controls was generally more difficult (AUC of all sensor locations combined 0.76, 95% CI 0.62-0.90). The video recordings revealed that the positioning of the hands during real-life gait had a substantial impact on the power spectral density of both the wrist and pants pocket sensor.

CONCLUSIONS:

We present a new video-referenced data set that includes unscripted activities in and around the participants' homes. Using this data set, we show the feasibility of using sensor-based analysis of real-life gait to monitor motor fluctuations with a single sensor location. Future work may assess the value of contextual sensors to control for real-world confounders.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Transtornos Motores / Dispositivos Eletrônicos Vestíveis / Marcha / Monitorização Fisiológica Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Transtornos Motores / Dispositivos Eletrônicos Vestíveis / Marcha / Monitorização Fisiológica Idioma: En Ano de publicação: 2020 Tipo de documento: Article