Your browser doesn't support javascript.
loading
Fluorescent Noble Metal Nanoclusters Loaded Protein Hydrogel Exhibiting Anti-Biofouling and Self-Healing Properties for Electrochemiluminescence Biosensing Applications.
Han, Cuiyan; Guo, Weiwei.
Afiliação
  • Han C; College of Chemistry, Research Centre for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin, 300071, P. R. China.
  • Guo W; College of Chemistry, Research Centre for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin, 300071, P. R. China.
Small ; 16(45): e2002621, 2020 11.
Article em En | MEDLINE | ID: mdl-33078529
ABSTRACT
Electrochemiluminescence (ECL) showed great potential in various analytical applications, especially in the sensing of biotargets, taking advantage of its high sensitivity, selectivity, ease of spatial and temporal control, and simplified optical setup. However, during the sensing of complex biological samples, ECL sensors often suffered severe interferences from unavoidable nonspecific-binding of biomacromolecules and physical damages of ECL sensing interfaces. Herein, a hydrogel based ECL biosensing system exhibiting excellent anti-biofouling and self-healing properties is developed. A protein hydrogel composed of bovine serum albumin (BSA) directed fluorescent Au/Ag alloy nanoclusters (Au/Ag NCs) is applied in building ECL sensing systems. The hydrogel matrix facilitates the immobilization of fluorescent Au/Ag NCs as excellent ECL probes, and the porous hydrophilic structure allows the free diffusion of small molecular biotargets while rejecting macromolecular interferences. Moreover, the hydrogel exhibits excellent self-healing property, with the ECL intensity recovered rapidly in 10 min after cutting. The hydrogel ECL system is successfully applied in sensing glutathione (GSH) in serum, confirming the applicability of the hydrogel based anti-biofouling ECL sensing system in sensing complex biological samples. This research may inspire the development of novel anti-biofouling and self-healing ECL biosensors for biosensing applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Idioma: En Ano de publicação: 2020 Tipo de documento: Article