Your browser doesn't support javascript.
loading
Photon Counting Imaging with Low Noise and a Wide Dynamic Range for Aurora Observations.
Han, Zhen-Wei; Song, Ke-Fei; Zhang, Hong-Ji; Yu, Miao; He, Ling-Ping; Guo, Quan-Feng; Wang, Xue; Liu, Yang; Chen, Bo.
Afiliação
  • Han ZW; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Song KF; Daheng School, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhang HJ; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Yu M; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • He LP; Shanghai Institute of Satellite Engineering, Shanghai 200240, China.
  • Guo QF; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Wang X; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Liu Y; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Chen B; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Sensors (Basel) ; 20(20)2020 Oct 21.
Article em En | MEDLINE | ID: mdl-33096841
ABSTRACT
The radiation intensity of observed auroras in the far-ultraviolet (FUV) band varies dramatically with location for aerospace applications, requiring a photon counting imaging apparatus with a wide dynamic range. However, combining high spatial resolution imaging with high event rates is technically challenging. We developed an FUV photon counting imaging system for aurora observation. Our system mainly consists of a microchannel plate (MCP) stack readout using a wedge strip anode (WSA) with charge induction and high-speed electronics, such as a charge sensitive amplifier (CSA) and pulse shaper. Moreover, we constructed an anode readout model and a time response model for readout circuits to investigate the counting error in high counting rate applications. This system supports global rates of 500 kilo counts, 0.610 dark counts s-1 cm-2 at an ambient temperature of 300 K and 111 µm spatial resolution at 400 kilo counts s-1 (kcps). We demonstrate an obvious photon count loss at incident intensities close to the counting capacity of the system. To preserve image quality, the response time should be improved and some noise performance may be sacrificed. Finally, we also describe the correlation between counting rate and imaging resolution, which further guides the design of space observation instruments.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article