Your browser doesn't support javascript.
loading
[Serum polychlorinated biphenyls in workers of a second-smelting steel mill]. / Policlorobifenili sierici nei lavoratori di una acciaieria di seconda fusione.
Sartorelli, Pietro; Orsi, Daniela; Minerva, Savino; Pedersini, Paolo; Mingotti, Osvaldo; Fiorentino, Maria Lorena; Cottica, Danilo.
Afiliação
  • Sartorelli P; Dipartimento di Biotecnologie mediche Università degli Studi di Siena, AOU Senese, Viale Bracci 16, 53100 Siena, Italy.
  • Orsi D; Dipartimento di Biotecnologie mediche Università degli Studi di Siena, AOU Senese, Viale Bracci 16, 53100 Siena, Italy.
  • Minerva S; Dipartimento di Biotecnologie mediche Università degli Studi di Siena, AOU Senese, Viale Bracci 16, 53100 Siena, Italy.
  • Pedersini P; Sias s.r.l., Via Carabioli 6/8 Cellatica, Brescia, Italy.
  • Mingotti O; Alfa Acciai S.p.A., Via San Polo 152, Brescia, Italy.
  • Fiorentino ML; Centro Ricerche Ambientali, Istituti Clinici Scientifici Maugeri, S.p.A. SB, Pavia-Padova, Padova, Italy.
  • Cottica D; Centro Ricerche Ambientali, Istituti Clinici Scientifici Maugeri, S.p.A. SB, Pavia-Padova, Padova, Italy.
G Ital Med Lav Ergon ; 42(3): 140-144, 2020 09.
Article em It | MEDLINE | ID: mdl-33119973
SUMMARY: In the steel industry polychlorodibenzodioxins (PCDD), polychlorinated dibenzofurans (PCDF) and polychlorinated biphenyls (PCBs) may be present deriving from the fusion of ferrous and non-ferrous scrap, as well as for the thermal decomposition of the plastic materials (thermoplastic and thermosetting resins) contained therein and not removed before melting at high temperatures. The aim of the study was to assess in 52 workers of a secondmelting steel plant the PCBs exposure deriving from the manual handling of ferrous scrap waste eventually contaminated. The population was divided by production department (scrap, casting and office). Static air sampling of PCDD, PCDF, PCBs and biological monitoring of serum dioxin-like PCBs (DL-PCBs) were performed. The comparison of serum DL-PCB values between workers from the scrap department and those from the casting did not find any statistically significant differences (Mann- Whitney U test). The range of serum DL-PCBs was 7.74-78.55 ng/g lipids with an average of 24.21 ng/g lipids, much lower than the reference values measured in the Italian general population in 2011. Mean and median TEQ WHO 1998 of DL-PCBs were 0.22 pg/g lipids and 0.15 pg/g lipids respectively. The low concentrations of serum DL-PCBS in the studied population can be explained by the progressive reduction of environmental PCBs contamination.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Bifenilos Policlorados / Poluentes Ocupacionais do Ar / Dibenzodioxinas Policloradas / Ferreiros / Metalurgia Idioma: It Ano de publicação: 2020 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Bifenilos Policlorados / Poluentes Ocupacionais do Ar / Dibenzodioxinas Policloradas / Ferreiros / Metalurgia Idioma: It Ano de publicação: 2020 Tipo de documento: Article