Your browser doesn't support javascript.
loading
A Custom-Made Orthodontic Mini-Implant-Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile.
Popa, Adelina; Dehelean, Cristina; Calniceanu, Horia; Watz, Claudia; Brad, Silviu; Sinescu, Cosmin; Marcu, Olivia A; Popa, Casiana Simina; Avram, Stefana; Nicolov, Mirela; Szuhanek, Camelia A.
Afiliação
  • Popa A; 2nd Department of Orthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Dehelean C; 2nd Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Calniceanu H; 1st Department/Periodontology, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Watz C; 1st Department of Pharmaceutical Physics and Biophysics, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Brad S; 2nd Department of Radiology, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Sinescu C; 2nd Department of Prostheses Technology and Dental Material, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Marcu OA; Dental Medicine Department, Faculty of Medicine and Pharmacy, University of Oradea, 410087 Oradea, Romania.
  • Popa CS; PAN Dental X RAY, 310337 Arad, Romania.
  • Avram S; 2nd Department of Pharmacognosy, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Nicolov M; 1st Department of Pharmaceutical Physics and Biophysics, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
  • Szuhanek CA; 2nd Department of Orthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Materials (Basel) ; 13(21)2020 Oct 27.
Article em En | MEDLINE | ID: mdl-33120951
BACKGROUND: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. MATERIALS AND METHODS: Three-dimensional finite element models of the maxilla were created and a custom-made, self-drilling, tapered mini-implant was designed. For the pull-out test, 12 simulations were performed, sequentially increasing the thickness of the cortical bone (1, 1.5 and 2 mm) and the insertion angle (30°, 60°, 90°, 120°). For the force analysis, 24 simulations were performed using an experimental orthodontic traction force of 2 N both in the horizontal and vertical axis. RESULTS: Insertion angle and CBT have significant impact on force reaction values (p < 0.05). Cortical bone stress had the lowest value when the mini-implant had a 30° insertion angle and the highest value when the implant had a 120° insertion angle, while the CBT was 1 mm. Cortical bone stress had the lowest value with an insertion angle of 90° and the highest value when the implant was inserted at an angle of 30°, while the CBT was 2 mm independent of the force direction. Regarding the biosafety profile of the mini-implant alloy, the present results reveal that the custom-made mini-implant presents good biocompatibility. CONCLUSIONS: When the CBT is reduced, we recommend inclined insertion while, when the CBT is appropriate, perpendicular insertion is advised.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article