Your browser doesn't support javascript.
loading
Validation of a SARS-CoV-2 RNA RT-PCR assay for high-throughput testing in blood of COVID-19 convalescent plasma donors and patients.
Strasser, Erwin F; Steininger, Philipp A; Korn, Klaus; Achenbach, Susanne; Tenbusch, Matthias; Cunningham, Sarah; Zimmermann, Robert; Überla, Klaus; Hackstein, Holger.
Afiliação
  • Strasser EF; Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Steininger PA; Institute of Clinical and Molecular Virology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Korn K; Institute of Clinical and Molecular Virology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Achenbach S; Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Tenbusch M; Institute of Clinical and Molecular Virology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Cunningham S; Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Zimmermann R; Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Überla K; Institute of Clinical and Molecular Virology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Hackstein H; Department of Transfusion Medicine and Hemostaseology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Transfusion ; 61(2): 368-374, 2021 02.
Article em En | MEDLINE | ID: mdl-33125162
BACKGROUND: The frequency of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNAemia in blood donors is uncertain. Thus, assays for SARS-CoV-2 RNA detection in blood, validated on commercially available polymerase chain reaction (PCR) systems, are required to allow a good comparability of data. STUDY DESIGN AND METHODS: The cobas SARS-CoV-2 dual-target reverse transcriptase PCR (RT-PCR) assay, licensed for respiratory swab SARS-CoV-2 RNA testing, was validated for detection of viral RNA in blood. For the validation panel, SARS-CoV-2-positive plasma samples were prepared by spiking SARS-CoV-2-positive respiratory specimens in negative human plasma. The 95% limit of detection (LOD95) was determined by probit analysis. For clinical validation, coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) donors and patients with COVID-19 with a severe disease course treated in an intensive care unit (ICU) were included. RESULTS: The validation of the SARS-CoV-2 RT-PCR assay for blood demonstrated high sensitivity and specificity and intra- and inter-assay precision and efficiency. The LOD95 for SARS-CoV-2 RNA was 5.0 genome copies/mL (95% confidence interval [CI], 3.3-12 copies/mL) for target 1 and 4.3 genome copies/mL (95% CI, 2.9-10 copies/mL) for target 2. In a cohort of 39 CCP donors with 66 CCP donations no SARS-CoV-2 RNA in plasma was detected. Screening of 25 blood samples of 19 ICU patients with COVID-19 showed six positive results for SARS-CoV-2 RNA in at least one target of the assay. CONCLUSION: The SARS-CoV-2 RNA assay, only licensed for respiratory swabs, performed on a PCR system for high-throughput testing, showed a good assay performance for blood testing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Idioma: En Ano de publicação: 2021 Tipo de documento: Article