Computational Biomechanical Analysis of Engaging and Nonengaging Abutments for Implant Screw-Retained Fixed Dental Prostheses.
Savignano, Roberto; Soltanzadeh, Pooya; Suprono, Montry S.
Afiliação
  • Savignano R; Center for Dental Research, Loma Linda University School of Dentistry, Loma Linda, CA.
  • Soltanzadeh P; Division of General Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA.
  • Suprono MS; Center for Dental Research, Loma Linda University School of Dentistry, Loma Linda, CA.
J Prosthodont ; 30(7): 604-609, 2021 Aug.
Article em En | MEDLINE | ID: mdl-33196135
PURPOSE: To evaluate the stress distribution, using 3-dimensional finite element analysis (FEA), on different implant components of a mandibular screw-retained fixed dental prosthesis (FDP) situation when using different combinations of engaging and nonengaging abutments. MATERIAL AND METHODS: A model of artificial bone was digitally designed. Dental implants were positioned in the lower right posterior area of teeth #'s 28 (premolar - pm) and 30 (molar - m). Restorative implant components were digitally designed and placed into the implant model. Four different implant abutment situations were simulated through FEA: (1) Both engaging abutments (mE-pmE), (2) both nonengaging (mNE-pmNE), (3) molar nonengaging and premolar engaging (mNE-pmE), and (4) molar engaging and premolar nonengaging (mE-pmNE). Thirty-five (35) Ncm preload to the abutment screws and 160 N static load at 45° angle to the occlusal plane were applied in each group. RESULTS: The equivalent Von Mises stress was measured on each component. Stress distribution changed among the different configurations and ranged from 516.0 to 1304.6 MPa in the implants, and from 554.6 to 994.5 MPa with the abutments. Higher stress was found for the mNE-pmNE designs (1078.6-1106.9 MPa). Engaging and nonengaging abutments had different stress distributions on the screw (698.8-902.5 MPa). Peak stress areas were located on the upper part of the screws for the nonengaging configuration, and on the lower areas for the engaging abutments. The sum of the stress on both implants decreased in the following order: mNE-pmNE > mE-pmNE > mNE-pmE > mE-pmE. CONCLUSION: Under conditions of this study, abutment design produced different stress patterns to the implant components. The lowest and most balanced stress distribution was found for the mE-pmE configuration followed by the mNE-pmE configuration.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Prótese Dentária Fixada por Implante Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários / Prótese Dentária Fixada por Implante Idioma: En Ano de publicação: 2021 Tipo de documento: Article