Remote monitoring of cardiac implantable devices during COVID-19 outbreak: "keep people safe" and "focus only on health care needs".
Iacopino, Saverio; Placentino, Filippo; Colella, Jacopo; Pesce, Francesca; Pardeo, Antonino; Filannino, Pasquale; Artale, Paolo; Desiro, Dalila; Sorrenti, Paolo; Campagna, Giuseppe; Fabiano, Gennaro; Peluso, Gianluca; Giacopelli, Daniele; Petretta, Andrea.
Afiliação
  • Iacopino S; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Placentino F; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Colella J; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Pesce F; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Pardeo A; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Filannino P; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Artale P; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Desiro D; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Sorrenti P; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Campagna G; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Fabiano G; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Peluso G; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
  • Giacopelli D; Clinical Research, BIOTRONIK Italia S.p.a, Vimodrone, Italy.
  • Petretta A; Arrhythnology Department, Maria Cecilia Hospital, Cotignola, Italy.
Acta Cardiol ; 76(2): 158-161, 2021 Apr.
Article em En | MEDLINE | ID: mdl-33203312
ABSTRACT

BACKGROUND:

The COVID-19 pandemic has challenged the ability of health care organisations to provide adequate care. We report the experience of a national tertiary electrophysiology centre in the management of patients with cardiac implantable electronic devices (CIEDs) through the use of a fully remote follow-up model.

METHODS:

We daily and prospectively collected remote monitoring (RM) relevant findings and following clinical actions performed from March 10th to April 3rd 2020, a period of suspension of routine ambulatory activity due to the national lockdown.

RESULTS:

During the study period (25 days), we received 2,215 transmissions from 2,955 devices. Among them, 129 patients reported potential clinically actionable RM observations (event rate 12.0/1000 patient-week). In 77 patients (60%), RM events triggered a clinical action, but only 5 patients needed an urgent in-hospital access (4 urgent procedures and 1 device reprogramming).

CONCLUSIONS:

In the unprecedented COVID-19 pandemic, RM became an essential tool in healthcare delivery for CIED patients. We observed that RM was effective in "keep people safe" and "focus only on individuals with health care needs".