Your browser doesn't support javascript.
loading
Phosphorescence of thermally altered human bone.
Krap, Tristan; Busscher, Loes; Oostra, Roelof-Jan; Aalders, Maurice C G; Duijst, Wilma.
Afiliação
  • Krap T; Maastricht University, Maastricht, The Netherlands. t.krap@amc.nl.
  • Busscher L; Department of Medical Biology, Section Anatomy, Amsterdam University Medical Centre, Location Academic Medical Centre, Meibergdreef 15, 1105 AZ, Amsterdam, The Netherlands. t.krap@amc.nl.
  • Oostra RJ; Ars Cognoscendi Foundation for Legal and Forensic Medicine, Wezep, The Netherlands. t.krap@amc.nl.
  • Aalders MCG; Department of Life Sciences and Technology-Biotechnology-Forensic Science, Van Hall Larenstein, University of Applied Sciences, Leeuwarden, The Netherlands. t.krap@amc.nl.
  • Duijst W; Department of Life Sciences and Technology-Biotechnology-Forensic Science, Van Hall Larenstein, University of Applied Sciences, Leeuwarden, The Netherlands.
Int J Legal Med ; 135(3): 1025-1034, 2021 May.
Article em En | MEDLINE | ID: mdl-33210233
ABSTRACT
Bone has photoluminescent characteristics that can aid the analysis of thermally altered human skeletal remains as part of the forensic anthropological investigation. Photoluminescence stands collectively for fluorescence and phosphorescence. Because the difference in lifetime between fluorescence and phosphorescence is usually in the range of nano- to microseconds, it is only possible to visually determine whether bone phosphoresces when the lifetime is long enough to be observed. For this study, a distinction was made between long-decay and short-decay phosphorescence. So far, it was unknown whether (thermally altered) human bone emits long-decay phosphorescence after being illuminated and, thus, whether phosphorescence contributes to the observed photoluminescence. If so, whether the observable phosphorescence is dependent on temperature, exposure duration, surrounding medium, bone type, skeletal element, and excitation light and could aid the temperature estimation of heated bone fragments. In this study, bone samples were subjected to heat in the range of from room temperature to 900 °C for various durations in either air or adipose as surrounding medium. In addition, different skeletal elements of a human cadaver were recollected after cremation in a crematorium. Both sample collections were illuminated with light of different bandwidths and visually inspected for phosphorescence and photoluminescence. The samples were scored by means of a scoring index for the intensity of long-decay phosphorescence and photographically documented. The results show that thermally altered human bone fragments do phosphoresce. The observed phosphorescence is more dependent on temperature than on exposure duration, surrounding medium or skeletal element. Of the used wavelength bands, ultraviolet light provided the most temperature-related information, showing changes in both phosphorescence intensity and emission spectrum. Long-decay phosphorescence and fluorescence with short-decay phosphorescence coincide; however, there are also temperature-dependent differences. It is therefore concluded that phosphorescence contributes to the observable photoluminescence and that the visibly observable phosphorescent characteristics can aid the temperature estimation of cremated human skeletal fragments.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Osso e Ossos / Luminescência / Restos Mortais / Medições Luminescentes Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Osso e Ossos / Luminescência / Restos Mortais / Medições Luminescentes Idioma: En Ano de publicação: 2021 Tipo de documento: Article