Your browser doesn't support javascript.
loading
Surface Acoustic Wave Sensor for C-Reactive Protein Detection.
Jeng, Ming-Jer; Sharma, Mukta; Li, Ying-Chang; Lu, Yi-Chen; Yu, Chia-Yu; Tsai, Chia-Lung; Huang, Shiang-Fu; Chang, Liann-Be; Lai, Chao-Sung.
Afiliação
  • Jeng MJ; Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Sharma M; Department of Otolaryngology-Head and Neck Surgery, Chang Gung Memorial Hospital, Linkou 244, Taiwan.
  • Li YC; Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Lu YC; Green Technology Research Center, Chang Gung University, Taoyuan 333, Taiwan.
  • Yu CY; Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Tsai CL; Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Huang SF; Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Chang LB; Department of Otolaryngology-Head and Neck Surgery, Chang Gung Memorial Hospital, Linkou 244, Taiwan.
  • Lai CS; Department of Otolaryngology-Head and Neck Surgery, Chang Gung Memorial Hospital, Linkou 244, Taiwan.
Sensors (Basel) ; 20(22)2020 Nov 19.
Article em En | MEDLINE | ID: mdl-33228249
ABSTRACT
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 µg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 µg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Som / Proteína C-Reativa / Doenças Cardiovasculares Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Som / Proteína C-Reativa / Doenças Cardiovasculares Idioma: En Ano de publicação: 2020 Tipo de documento: Article