Your browser doesn't support javascript.
loading
Clinical Assessment of 177Lu-DOTATATE Quantification by Comparison of SUV-Based Parameters Measured on Both Post-PRRT SPECT/CT and 68Ga-DOTATOC PET/CT in Patients With Neuroendocrine Tumors: A Feasibility Study.
Thuillier, Philippe; Maajem, Meriem; Schick, Ulrike; Blanc-Beguin, Frédérique; Hennebicq, Simon; Metges, Jean-Philippe; Salaun, Pierre-Yves; Kerlan, Véronique; Bourhis, David; Abgral, Ronan.
Afiliação
  • Maajem M; Department of Nuclear Medicine.
  • Schick U; Department of Radiotherapy.
  • Metges JP; Department of Oncology, University Hospital of Brest, Brest, France.
Clin Nucl Med ; 46(2): 111-118, 2021 Feb 01.
Article em En | MEDLINE | ID: mdl-33234927
PATIENTS AND METHODS: Patients with WD-GEP-NET who benefited from a pretherapeutic 68Ga-DOTATOC PET/CT and a 177Lu-DOTATATE SPECT/CT after the cycle 1 of peptide receptor radionuclide therapy were prospectively included. SPECT/CT acquisitions were performed on a system calibrated with a conversion factor of 9.48 counts/MBq per second and were reconstructed with an iterative algorithm allowing quantification using the SPECTRA Quant software (MIM Software, Cleveland, OH). For each patient, different SUV parameters were recorded on both PET/CT (Ga parameters) and SPECT/CT (Lu parameters) for comparison: physiological uptakes (liver/spleen), tumor uptake (1-10/patient; SUVmax, SUVmean, SUVpeak, MTV), tumor-to-liver and tumor-to-spleen ratios according to liver/spleen SUVmax and SUVmean (TLRmax, TLRmean, TSRmax, and TSRmean, respectively). RESULTS: Ten patients (8 female; 2 male) aged from 50 to 83 years presenting with a metastatic progressive WD-GEP-NET (7 small intestine, 2 pancreas, 1 rectum) were included. Median values of lesional Lu-SUV were significantly lower than the corresponding Ga-SUV (P < 0.001), whereas median values of lesional Lu-MTV, Lu-TLR, and Lu-TSR were significantly higher than the corresponding Ga-MTV, Ga-TLR, and Ga-TSR (P < 0.02). Pearson correlation coefficients were strong for both SUV and MTV parameters (0.779-0.845), weak for TLR parameters (0.365-0.394), and moderate-to-strong for TSR parameters (0.676-0.750). CONCLUSIONS: Our results suggest the feasibility of 177Lu-DOTATATE SPECT/CT quantification in clinical practice and show a strong correlation of several SUV-based parameters with the corresponding in 68Ga-DOTATOC PET/CT.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Neoplasias Pancreáticas / Neoplasias Gástricas / Octreotida / Receptores de Peptídeos / Tumores Neuroendócrinos / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Neoplasias Intestinais Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Neoplasias Pancreáticas / Neoplasias Gástricas / Octreotida / Receptores de Peptídeos / Tumores Neuroendócrinos / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Neoplasias Intestinais Idioma: En Ano de publicação: 2021 Tipo de documento: Article