Your browser doesn't support javascript.
loading
Accuracy and Workflow Improvements for Responsive Neurostimulation Hippocampal Depth Electrode Placement Using Robotic Stereotaxy.
Karas, Patrick J; Giridharan, Nisha; Treiber, Jeffrey M; Prablek, Marc A; Khan, A Basit; Shofty, Ben; Krishnan, Vaishnav; Chu, Jennifer; Van Ness, Paul C; Maheshwari, Atul; Haneef, Zulfi; Gavvala, Jay R; Sheth, Sameer A.
Afiliação
  • Karas PJ; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Giridharan N; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Treiber JM; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Prablek MA; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Khan AB; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Shofty B; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
  • Krishnan V; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Chu J; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Van Ness PC; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Maheshwari A; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Haneef Z; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Gavvala JR; Department of Neurology, Comprehensive Epilepsy Center, Baylor College of Medicine, Houston, TX, United States.
  • Sheth SA; Department of Neurosurgery, Baylor College of Medicine, Houston, TX, United States.
Front Neurol ; 11: 590825, 2020.
Article em En | MEDLINE | ID: mdl-33424745
ABSTRACT

Background:

Robotic stereotaxy is increasingly common in epilepsy surgery for the implantation of stereo-electroencephalography (sEEG) electrodes for intracranial seizure monitoring. The use of robots is also gaining popularity for permanent stereotactic lead implantation applications such as in deep brain stimulation and responsive neurostimulation (RNS) procedures.

Objective:

We describe the evolution of our robotic stereotactic implantation technique for placement of occipital-approach hippocampal RNS depth leads.

Methods:

We performed a retrospective review of 10 consecutive patients who underwent robotic RNS hippocampal depth electrode implantation. Accuracy of depth lead implantation was measured by registering intraoperative post-implantation fluoroscopic CT images and post-operative CT scans with the stereotactic plan to measure implantation accuracy. Seizure data were also collected from the RNS devices and analyzed to obtain initial seizure control outcome estimates.

Results:

Ten patients underwent occipital-approach hippocampal RNS depth electrode placement for medically refractory epilepsy. A total of 18 depth electrodes were included in the analysis. Six patients (10 electrodes) were implanted in the supine position, with mean target radial error of 1.9 ± 0.9 mm (mean ± SD). Four patients (8 electrodes) were implanted in the prone position, with mean radial error of 0.8 ± 0.3 mm. The radial error was significantly smaller when electrodes were implanted in the prone position compared to the supine position (p = 0.002). Early results (median follow-up time 7.4 months) demonstrate mean seizure frequency reduction of 26% (n = 8), with 37.5% achieving ≥50% reduction in seizure frequency as measured by RNS long episode counts.

Conclusion:

Prone positioning for robotic implantation of occipital-approach hippocampal RNS depth electrodes led to lower radial target error compared to supine positioning. The robotic platform offers a number of workflow advantages over traditional frame-based approaches, including parallel rather than serial operation in a bilateral case, decreased concern regarding human error in setting frame coordinates, and surgeon comfort.