Your browser doesn't support javascript.
loading
Ultrasound-Guided Biceps Tendon Sheath Injections Frequently Extravasate Into the Glenohumeral Joint.
Slevin, John; Joyce, Meghan; Galvin, Joseph W; Mahlon, Michael A; Grant, Matthew D; Eichinger, Josef K; Grassbaugh, Jason A.
Afiliação
  • Slevin J; Madigan Army Medical Center, Joint Base Lewis-McChord, Washington, U.S.A.
  • Joyce M; San Antonio Military Medical Center, JBSA Fort Sam Houston, Texas, U.S.A.
  • Galvin JW; Madigan Army Medical Center, Joint Base Lewis-McChord, Washington, U.S.A.
  • Mahlon MA; Madigan Army Medical Center, Joint Base Lewis-McChord, Washington, U.S.A.
  • Grant MD; Madigan Army Medical Center, Joint Base Lewis-McChord, Washington, U.S.A.
  • Eichinger JK; Department of Orthopaedics, Medical University of South Carolina, Charleston, South Carolina, U.S.A.. Electronic address: joe.eichinger@gmail.com.
  • Grassbaugh JA; Madigan Army Medical Center, Joint Base Lewis-McChord, Washington, U.S.A.
Arthroscopy ; 37(6): 1711-1716, 2021 06.
Article em En | MEDLINE | ID: mdl-33453348
PURPOSE: To evaluate the frequency of glenohumeral joint extravasation of ultrasound (US)-guided biceps tendon sheath injections. METHODS: Fifty shoulders with a clinical diagnosis of bicipital tenosynovitis pain received a US-guided biceps sheath injection with anesthetic, steroid, and contrast (5.0 mL mixture) followed immediately by orthogonal radiographs to localize the anatomic distribution of the injection. Radiographic evaluation of contrast localization was determined and interobserver reliability calculated. RESULTS: All 50 postinjection radiographs (100%) demonstrated contrast within the biceps tendon sheath. In addition, 30 of 50 (60%) radiographs also revealed contrast in the glenohumeral joint. Interobserver reliability for determination of intraarticular contrast was good (kappa value 0.87). CONCLUSIONS: US-guided bicipital sheath injections reproducibly result in intrasheath placement of injection fluid. Bicipital sheath injections performed with 5 mL of volume result in partial extravasation into the joint 60% of the time. These data may be useful for surgeons who use the results of diagnostic biceps injections for diagnosis and surgical decision-making. LEVEL OF EVIDENCE: III, prospective cohort study, diagnosis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro Idioma: En Ano de publicação: 2021 Tipo de documento: Article