Your browser doesn't support javascript.
loading
Analyzing the heart rhythm during chest compressions: Performance and clinical value of a new AED algorithm.
de Graaf, Corina; Beesems, Stefanie G; Oud, Sharon; Stickney, Ronald E; Piraino, Daniel W; Chapman, Fred W; Koster, Rudolph W.
Afiliação
  • de Graaf C; Amsterdam UMC, Academic Medical Center (AMC), Heart Center, Department of Cardiology, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. Electronic address: c.degraaf@amsterdamumc.nl.
  • Beesems SG; Amsterdam UMC, Academic Medical Center (AMC), Heart Center, Department of Cardiology, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
  • Oud S; Amsterdam UMC, Academic Medical Center (AMC), Heart Center, Department of Cardiology, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
  • Stickney RE; Stryker Emergency Care, Redmond, WA 98052, USA.
  • Piraino DW; Stryker Emergency Care, Redmond, WA 98052, USA.
  • Chapman FW; Stryker Emergency Care, Redmond, WA 98052, USA.
  • Koster RW; Amsterdam UMC, Academic Medical Center (AMC), Heart Center, Department of Cardiology, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Resuscitation ; 162: 320-328, 2021 05.
Article em En | MEDLINE | ID: mdl-33460749
PURPOSE: Automated external defibrillators (AED) prompt the rescuer to stop chest compressions (CC) for ECG analysis during out-of-hospital cardiac arrest (OHCA). We assessed the diagnostic accuracy and clinical benefit of a new AED algorithm (cprINSIGHT), which analyzes ECG and impedance signals during CC, allowing rhythm analysis with ongoing chest compressions. METHODS: Amsterdam Police and Fire Fighters used a conventional AED in 2016-2017 (control) and an AED with cprINSIGHT in 2018-2019 (intervention). In the intervention AED, cprINSIGHT was activated after the first (conventional) analysis. This algorithm classified the rhythm as "shockable" (S) and "non-shockable" (NS), or "pause needed". Sensitivity for S, specificity for NS with 90% lower confidence limit (LCL), chest compression fractions (CCF) and pre-shock pause were compared between control and intervention cases accounting for multiple observations per patient. RESULTS: Data from 465 control and 425 intervention cases were analyzed. cprINSIGHT reached a decision during CC in 70% of analyses. Sensitivity of the intervention AED was 96%, (LCL 93%) and specificity was 98% (LCL 97%), both not significantly different from control. Intervention cases had a shorter median pre-shock pause compared to control cases (8 s vs 22 s, p < 0.001) and higher median CCF (86% vs 80%, P < 0.001). CONCLUSION: AEDs with cprINSIGHT analyzed the ECG during chest compressions in 70% of analyses with 96% sensitivity and 98% specificity when it made a S or a NS decision. Compared to conventional AEDs, cprINSIGHT leads to a significantly shorter pre-shock pause and a significant increase in CCF.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Extra-Hospitalar Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar / Parada Cardíaca Extra-Hospitalar Idioma: En Ano de publicação: 2021 Tipo de documento: Article