3D Printable, Modified Trephine Designs for Consistent Anterior Lamellar Keratectomy Wounds in Rabbits.
Chen, Fang; Buickians, David; Le, Peter; Xia, Xin; Montague-Alamin, Spencer Q; Blanco Varela, Ignacio Blanco; Mundy, David C; Logan, Caitlin M; Myung, David.
Afiliação
  • Chen F; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
  • Buickians D; VA Palo Alto Health Care System, Palo Alto, California, USA.
  • Le P; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
  • Xia X; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
  • Montague-Alamin SQ; VA Palo Alto Health Care System, Palo Alto, California, USA.
  • Blanco Varela IB; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
  • Mundy DC; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
  • Logan CM; Chemical Engineering, Stanford University, Stanford, California, USA.
  • Myung D; Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
Curr Eye Res ; 46(8): 1105-1114, 2021 08.
Article em En | MEDLINE | ID: mdl-33474996
PURPOSE: Our goal is to develop a low-cost tool that can be used to create consistent, partial-thickness defects in rabbit and other large animals with minimal surgical training and that can facilitate pre-clinical testing of lamellar and in situ-forming biosynthetic matrix materials for corneal repair. MATERIALS & METHODS: In this study, three modified trephines were designed to create deep corneal wound defects with consistent depth in large animals. The modified trephines incorporated either 3D-printed parts made from photopolymerizable resins, or custom-cut commercially available Teflon sheets. Wound defects were imaged with optical coherence tomography (OCT), and the depth was analyzed based on the OCT images. RESULTS: The results revealed that an inner-stopper guard trephine had the best performance in creating consistent and precise wound defect depth compared to modified vacuum trephine and custom guard vacuum trephine. A 75% ± 10% cut of the cornea was achieved with the inner-stopper guard trephine. The wound defect depth by created by the inner-stopper guard trephine was independent of the corneal thickness or size of the globes. Although the cut depth of the inner-stopper guard trephine differed by the experience-level of its users, the consistency (standard deviation) of the depth was independent of experience. CONCLUSIONS: Our studies provided three cost-efficient animal trephines that can create corneal wounds of consistent depth by lab researchers without extensive training in keratectomy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Córnea / Córnea / Modelos Animais de Doenças / Desenho de Equipamento / Impressão Tridimensional / Ferida Cirúrgica Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Córnea / Córnea / Modelos Animais de Doenças / Desenho de Equipamento / Impressão Tridimensional / Ferida Cirúrgica Idioma: En Ano de publicação: 2021 Tipo de documento: Article