Detection of Brevetoxin in Human Plasma by ELISA.
Cunningham, Brady R; Coleman, Rebecca M; Schaefer, Adam M; Hamelin, Elizabeth I; Johnson, Rudolph C.
Afiliação
  • Cunningham BR; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Coleman RM; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Schaefer AM; Harbor Branch Oceanographic Institute, Florida Atlantic University, Ft. Pierce, FL 34946, USA.
  • Hamelin EI; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Johnson RC; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
J Anal Toxicol ; 46(3): 322-327, 2022 Mar 21.
Article em En | MEDLINE | ID: mdl-33515246
ABSTRACT
Florida red tides have become more common and persistent in and around the Gulf of Mexico. When in bloom, red tides can produce brevetoxins in high concentrations, leading to human exposures primarily through contaminated food and ocean spray. The research described here includes adapting and validating a commercial brevetoxin water test kit for human plasma testing. Pooled plasma was fortified with a model brevetoxin, brevetoxin 3, at concentrations from 0.00500 to 3.00 ng/mL to generate calibration curves and quality control samples. The quantitative detection range was determined to be 0.0400-2.00 ng/mL brevetoxin 3 equivalents with inter- and intraday accuracies ranging from 94.0% to 109% and relative standard deviations <20%, which is within the US Food and Drug Administration guidelines for receptor-binding assays. Additionally, cross-reactivity was tested using 4 of the 10 known brevetoxins and 12 paralytic shellfish toxins. The cross-reactivity varied from 0.173% to 144% for the commercially available brevetoxin standards and 0% for the commercially available paralytic shellfish toxin standards. Fifty individual unexposed human plasma samples were measured to determine the limit of detection and endogenous interferences to the test. The validated method was used to test 31 plasma samples collected from humans potentially exposed to brevetoxins, detecting 11 positives. This method has been proven useful to measure human exposure to brevetoxins and can be applied to future exposure events.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dinoflagellida Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dinoflagellida Idioma: En Ano de publicação: 2022 Tipo de documento: Article