Your browser doesn't support javascript.
loading
Wavelet Transform and Deep Convolutional Neural Network-Based Smart Healthcare System for Gastrointestinal Disease Detection.
Mohapatra, Subhashree; Nayak, Janmenjoy; Mishra, Manohar; Pati, Girish Kumar; Naik, Bignaraj; Swarnkar, Tripti.
Afiliação
  • Mohapatra S; Department of Computer Science and Engineering, Siksha O Anusandhan (Deemed to Be University), Bhubaneswar, 751030, India.
  • Nayak J; Department of Computer Science, Aditya Institute of Technology and Management, Srikakulam, Andhra Pradesh, 532201, India. mailforjnayak@gmail.com.
  • Mishra M; Department of Electrical and Electronics Engineering, Siksha O Anusandhan Deemed to Be University, Bhubaneswar, 751030, India.
  • Pati GK; Department of Gastroenterology, Institute of Medical Science, SUM Hospital, Bhubaneswar, 751030, India.
  • Naik B; Department of Computer Application, Veer Surendra Sai University of Technology, Burla, 768018, India.
  • Swarnkar T; Department of Computer Application, Siksha O Anusandhan (Deemed to Be University), Bhubaneswar, 751030, India.
Interdiscip Sci ; 13(2): 212-228, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33566337
ABSTRACT
This work presents a smart healthcare system for the detection of various abnormalities present in the gastrointestinal (GI) region with the help of time-frequency analysis and convolutional neural network. In this regard, the KVASIR V2 dataset comprising of eight classes of GI-tract images such as Normal cecum, Normal pylorus, Normal Z-line, Esophagitis, Polyps, Ulcerative Colitis, Dyed and lifted polyp, and Dyed resection margins are used for training and validation. The initial phase of the work involves an image pre-processing step, followed by the extraction of approximate discrete wavelet transform coefficients. Each class of decomposed images is later given as input to a couple of considered convolutional neural network (CNN) models for training and testing in two different classification levels to recognize its predicted value. Afterward, the classification performance is measured through the following measuring indices accuracy, precision, recall, specificity, and F1 score. The experimental result shows 97.25% and 93.75% of accuracy in the first level and second level of classification, respectively. Lastly, a comparative performance analysis is carried out with several other previously published works on a similar dataset where the proposed approach performs better than its contemporary methods.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Ondaletas / Gastroenteropatias Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Ondaletas / Gastroenteropatias Idioma: En Ano de publicação: 2021 Tipo de documento: Article