Your browser doesn't support javascript.
loading
Esthetic elastomeric ligatures: Quantification of bacterial endotoxin in vitro and in vivo.
Pinto, Letícia Sgarbi; Nakane Matsumoto, Mírian Aiko; Romualdo, Priscilla Coutinho; Romano, Fábio Lourenço; da Silva, Raquel Assed Bezerra; da Silva, Léa Assed Bezerra; de Queiroz, Alexandra Mussolino; Nelson-Filho, Paulo.
Afiliação
  • Pinto LS; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. Electronic address: leticia_sgarbi@hotmail.com.
  • Nakane Matsumoto MA; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Romualdo PC; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Romano FL; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • da Silva RAB; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • da Silva LAB; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • de Queiroz AM; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Nelson-Filho P; Department of Pediatric Clinic, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
Am J Orthod Dentofacial Orthop ; 159(5): 660-665, 2021 May.
Article em En | MEDLINE | ID: mdl-33714568
INTRODUCTION: The objective of this study was to evaluate in vitro and in vivo bacterial endotoxin (LPS) adhesion in polyurethane and silicone esthetic elastomeric orthodontic ligatures. The null hypotheses tested were: (1) there is no LPS adhesion in esthetic elastomeric orthodontic ligatures; and (2) there is no difference in the LPS adhesion between different brands of these ligatures. METHODS: For the in vitro study, 4 types of esthetic elastomeric ligatures were used (Sani-Ties and Sili-Ties [Dentsply GAC, Islandia, NY;] and Mini Single Case Ligature Stick and Synergy low-friction ligatures [Rocky Mountain Orthodontics, Denver, Colo]), contaminated or not with endotoxin solution. Replicas of twisted wire and cast stainless steel ligatures were used as control. For the in vivo study, 10 male and 10 female patients, aged 15-30 years, received the same 4 types of ligatures, 1 of each inserted in the maxillary and mandibular canines, randomly. Twenty-one days later, the ligatures were removed, and endotoxin quantification was performed using the Limulus amebocyte lysate test. Data were analyzed (α = 0.05) using the Kruskal-Wallis test and Dunn's posttest or analysis of variance and Tukey's posttest. RESULTS: GAC silicone group had the lowest median contamination (1.15 endotoxin units/mL; P <0.0001) in vitro. In the in vivo study, the GAC silicone group had the lowest mean contamination (0.577 endotoxin units/mL; P <0.001). In both studies, the other groups did not present a significant difference when compared with each other (P >0.05). CONCLUSIONS: LPS exhibited an affinity for all the tested polyurethane and silicone elastomeric ligatures. GAC silicone ligatures presented with lower amounts of LPS attached to their surfaces. Thus, both null hypotheses were rejected.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Braquetes Ortodônticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Braquetes Ortodônticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article