Your browser doesn't support javascript.
loading
What is the impact of preserving the endothelium on saphenous vein graft performance? Comments on the 'NO' touch harvesting technique.
Samano, Ninos; Loesch, Andrzej; Dashwood, Michael R.
Afiliação
  • Samano N; Department of Cardiothoracic and Vascular Surgery, Örebro University, Örebro, Sweden.
  • Loesch A; Centre for Rheumatology, Royal Free Hospital Campus, University College Medical School, London, UK.
  • Dashwood MR; Surgical and Interventional Sciences, Royal Free Hospital Campus, University College Medical School, Pond Street, London, NW3 2QG, UK. m.dashwood@ucl.ac.uk.
J Cardiothorac Surg ; 16(1): 21, 2021 Mar 16.
Article em En | MEDLINE | ID: mdl-33726786
ABSTRACT
Saphenous veins used for coronary artery bypass surgery are subjected to considerable vascular trauma when harvested by conventional methods. This vascular damage is responsible, at least in part, for the inferior patency of the saphenous vein when compared with the internal thoracic artery. The performance of saphenous vein grafts is improved when this conduit is harvested atraumatically using the no-touch technique. There is growing evidence that the success of the no-touch technique is due to the preservation of a number of vascular structures including the endothelium, vasa vasorum and perivascular fat. There is conflicting evidence regarding the degree of endothelial damage to the endothelium of conventional versus no-touch saphenous vein grafts. In general, it has been shown that this single layer of cells lining the lumen exhibits considerable damage associated with a combination of vascular trauma and high pressure intraluminal distension. Increased platelet aggregation and thrombus formation at the exposed subendothelial membrane is due to a local reduction of endothelium-derived factors including nitric oxide. In addition, damage to the vasa vasorum of conventionally-harvested veins will reduce transmural blood flow, a condition shown to promote neointimal hyperplasia and atheroma formation. By stripping off the perivascular fat during conventional harvesting, mechanical support of the graft is reduced and the source of adipocyte-derived factors potentially beneficial for graft patency removed. While most agree that endothelial damage to the saphenous vein affects graft patency, the contribution of other tissue-derived factors affected by vascular damage at harvesting need to be considered.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Safena / Doença da Artéria Coronariana / Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Coleta de Tecidos e Órgãos / Óxido Nítrico Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Safena / Doença da Artéria Coronariana / Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Coleta de Tecidos e Órgãos / Óxido Nítrico Idioma: En Ano de publicação: 2021 Tipo de documento: Article