Your browser doesn't support javascript.
loading
3D Printing of Rapid, Low-Cost and Patient-Specific Models of Brain Vasculature for Use in Preoperative Planning in Clipping of Intracranial Aneurysms.
Blaszczyk, Maciej; Jabbar, Redwan; Szmyd, Bartosz; Radek, Maciej.
Afiliação
  • Blaszczyk M; Department of Neurosurgery, Spine and Peripheral Nerves Surgery, Medical University of Lódz, 90-549 Lódz, Poland.
  • Jabbar R; Department of Neurosurgery, Spine and Peripheral Nerves Surgery, Medical University of Lódz, 90-549 Lódz, Poland.
  • Szmyd B; Department of Neurosurgery, Spine and Peripheral Nerves Surgery, Medical University of Lódz, 90-549 Lódz, Poland.
  • Radek M; Department of Neurosurgery, Spine and Peripheral Nerves Surgery, Medical University of Lódz, 90-549 Lódz, Poland.
J Clin Med ; 10(6)2021 Mar 13.
Article em En | MEDLINE | ID: mdl-33805774
ABSTRACT
We developed a practical and cost-effective method of production of a 3D-printed model of the arterial Circle of Willis of patients treated because of an intracranial aneurysm. We present and explain the steps necessary to produce a 3D model from medical image data, and express the significant value such models have in patient-specific pre-operative planning as well as education. A Digital Imaging and Communications in Medicine (DICOM) viewer is used to create 3D visualization from a patient's Computed Tomography Angiography (CTA) images. After generating the reconstruction, we manually remove the anatomical components that we wish to exclude from the print by utilizing tools provided with the imaging software. We then export this 3D reconstructions file into a Standard Triangulation Language (STL) file which is then run through a "Slicer" software to generate a G-code file for the printer. After the print is complete, the supports created during the printing process are removed manually. The 3D-printed models we created were of good accuracy and scale. The median production time used for the models described in this manuscript was 4.4 h (range 3.9-4.5 h). Models were evaluated by neurosurgical teams at local hospital for quality and practicality for use in urgent and non-urgent care. We hope we have provided readers adequate insight into the equipment and software they would require to quickly produce their own accurate and cost-effective 3D models from CT angiography images. It has become quite clear to us that the cost-benefit ratio in the production of such a simplified model is worthwhile.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article