Your browser doesn't support javascript.
loading
Multicenter evaluation of the VITEK MS matrix-assisted laser desorption/ionization-time of flight mass spectrometry system for identification of bacteria, including Brucella, and yeasts.
Girard, Victoria; Monnin, Valérie; Giraud, Delphine; Polsinelli, Sophie; Caillé, Marion; Procop, Gary W; Tuohy, Marion; Wilson, Deborah; Richter, Sandra S; Kiss, Katalin; Clem, Kimberly; Tolli, Nicholas; Bridon, Laurence; Bradford, Constance; Blamey, Sara; Li, Jay; Pincus, David H.
Afiliação
  • Girard V; R&D Microbiology, bioMérieux sa, La Balme les Grottes, France. victoria.girard@biomerieux.com.
  • Monnin V; R&D Microbiology, bioMérieux sa, La Balme les Grottes, France.
  • Giraud D; R&D Microbiology, bioMérieux sa, La Balme les Grottes, France.
  • Polsinelli S; R&D Microbiology, bioMérieux sa, La Balme les Grottes, France.
  • Caillé M; R&D Microbiology, bioMérieux sa, La Balme les Grottes, France.
  • Procop GW; MSD, Clermont-Ferrand, France.
  • Tuohy M; Pathology & Laboratory Medicine Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Wilson D; Pathology & Laboratory Medicine Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Richter SS; Pathology & Laboratory Medicine Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Kiss K; Pathology & Laboratory Medicine Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Clem K; Medical Affairs, bioMérieux, Inc., Durham, NC, USA.
  • Tolli N; ATCC, Manassas, VA, USA.
  • Bridon L; ATCC, Manassas, VA, USA.
  • Bradford C; ATCC, Manassas, VA, USA.
  • Blamey S; Clinical Affairs, bioMérieux sa, Marcy L'Étoile, France.
  • Li J; Clinical Affairs, bioMérieux, Inc., St. Louis, MO, USA.
  • Pincus DH; Clinical Affairs, bioMérieux, Inc., St. Louis, MO, USA.
Eur J Clin Microbiol Infect Dis ; 40(9): 1909-1917, 2021 Sep.
Article em En | MEDLINE | ID: mdl-33837878
ABSTRACT
The use of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry has proven to be rapid and accurate for the majority of clinical isolates. Some gaps remain concerning rare, emerging, or highly pathogenic species, showing the need to continuously expand the databases. In this multicenter study, we evaluated the accuracy of the VITEK MS v3.2 database in identifying 1172 unique isolates compared to identification by DNA sequence analysis. A total of 93.6% of the isolates were identified to species or group/complex level. A remaining 5.2% of the isolates were identified to the genus level. Forty tests gave a result of no identification (0.9%) and 12 tests (0.3%) gave a discordant identification compared to the reference identification. VITEK MS is also the first MALDI-TOF MS system that is able to delineate the four members of the Acinetobacter baumannii complex at species level without any specific protocol or special analysis method. These findings demonstrate that the VITEK MS v3.2 database is highly accurate for the identification of bacteria and fungi encountered in the clinical laboratory as well as emerging species like Candida auris and the highly pathogenic Brucella species.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bactérias / Leveduras / Brucella / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bactérias / Leveduras / Brucella / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Idioma: En Ano de publicação: 2021 Tipo de documento: Article