Your browser doesn't support javascript.
loading
Do myopes have deficits in peripheral flicker sensitivity?
Hathibelagal, Amithavikram R; Manoharan, Manoj K; Verkicharla, Pavan K.
Afiliação
  • Hathibelagal AR; Brien Holden Institute of Optometry and Vision Sciences, Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Road No. 2, Banjara Hills, Kallam Anji Reddy Campus, Hyderabad 500034, India. Electronic address: amithavikram@lvpei.org.
  • Manoharan MK; Brien Holden Institute of Optometry and Vision Sciences, Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Road No. 2, Banjara Hills, Kallam Anji Reddy Campus, Hyderabad 500034, India; Myopia Research Lab - Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.
  • Verkicharla PK; Brien Holden Institute of Optometry and Vision Sciences, Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Road No. 2, Banjara Hills, Kallam Anji Reddy Campus, Hyderabad 500034, India; Myopia Research Lab - Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India. Electronic address: pavanverkicharla@lvpei.org.
J Optom ; 15(2): 138-144, 2022.
Article em En | MEDLINE | ID: mdl-33849791
ABSTRACT

PURPOSE:

Signals from the peripheral retina are important for myopia development. Unlike temporal vision, deficits in peripheral spatial visual functions of myopes have been investigated previously. This study investigated temporal contrast thresholds in emmetropes and myopes at different retinal eccentricities.

METHODS:

Forty-four young adults (mean age 23 ± 3 years) including 21 emmetropes (Spherical Equivalent (SE) +0.01 ± 0.30D) and 23 myopes (SE -3.98 ± 2.41D) participated in this prospective study. Flicker modulation thresholds (FMT) were determined monocularly (right eye) for 15 Hz flicker stimulus at 0°, nasal (23°, 10°) and temporal (-23°, -10°) retinal eccentricities along the horizontal meridian. FMTs were measured psychophysically using 5-adaptive interleaved staircases and threshold was taken as the average of the last 6 reversals.

RESULTS:

In both the groups (emmetropes and myopes), there was a naso-temporal asymmetry in FMTs with higher thresholds in the far temporal retina (Median; Interquartile range 40.97%; 17.06) than the nasal retina (28.07%; 9.36) (p < 0.001). Flicker modulation thresholds were significantly higher in myopes (30.58%; 12.15) compared to emmetropes (26.77%; 7.74; p = 0.04) at far nasal retina (23°), while at other eccentricities there was no effect (p > 0.05). Further sub-analysis revealed only high myopes (34.48 %, 21.9) showed significantly higher FMT compared to emmetropes (26.77%; 7.74; p = 0.04).

CONCLUSION:

Greater FMTs were seen in high myopes than that of emmetropes in the nasal retina. Further studies exploring the structural aspects of the myopic eye with FMT would provide a better understanding of role of flicker sensitivity in myopiogenesis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Emetropia / Miopia Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Emetropia / Miopia Idioma: En Ano de publicação: 2022 Tipo de documento: Article