Implications of component size and calibration error on digital templating for total hip arthroplasty. A visual matrix from a simple mathematical model.
Boese, Christoph Kolja; Rolvien, Tim; Trost, Matthias; Frink, Michael; Hubert, Jan; Beil, Frank Timo; Ries, Christian.
Afiliação
  • Boese CK; Department of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Cologne, Germany. k.boese@uke.de.
  • Rolvien T; Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. k.boese@uke.de.
  • Trost M; Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Frink M; Department of Orthopaedics and Traumatology, St. Josef-Hospital, University of Bochum, Bochum, Germany.
  • Hubert J; Center of Orthopedic and Trauma Surgery, University of Giessen and Marburg, Marburg, Germany.
  • Beil FT; Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Ries C; Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Int J Comput Assist Radiol Surg ; 16(6): 1037-1041, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33864566
OBJECTIVE: Preoperative digital templating is a standard procedure in total hip arthroplasty. Deviations between template size and final implant size may result from inaccurate calibration, templating as well as intraoperative decisions. So far, the explicit effect of calibration errors on templating has not been addressed adequately. MATERIALS AND METHODS: A mathematical simulation of calibration errors up to ± 24% was applied to the templating of acetabular cups (38 to 72 mm diameter). The effect of calibration errors on template component size as deviation from optimal size was calculated. RESULTS: The relationship between calibration error and component size deviation is inverse and linear. Calibration errors have a more pronounced effect on larger component sizes. Calibration errors of 2-6% result in templating errors of up to two component sizes. Common errors of up to 12% may result in templating errors of 3-4 sizes for common implant sizes. A tabular matrix visualizes the effect. CONCLUSION: Calibration errors play a significant role in component size selection during digital templating. Orthopedic surgeons should be aware of this effect and try to identify and address this source of error.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cuidados Pré-Operatórios / Artroplastia de Quadril / Articulação do Quadril / Prótese de Quadril / Modelos Teóricos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cuidados Pré-Operatórios / Artroplastia de Quadril / Articulação do Quadril / Prótese de Quadril / Modelos Teóricos Idioma: En Ano de publicação: 2021 Tipo de documento: Article