Validation of factor VIII activity for monitoring standard and extended half-life products and correlation to thrombin generation assays.
Augustsson, Cecilia; Norström, Eva; Lind, Vivian; Martin, Myriam; Astermark, Jan; Strandberg, Karin.
Afiliação
  • Augustsson C; Department of Clinical Chemistry and Pharmacology, Division of Laboratory Medicine, Coagulation, University and Regional Laboratories Region Skåne, Malmö, Sweden.
  • Norström E; Department of Translational Medicine, Lund University, Malmö, Sweden.
  • Lind V; Department of Clinical Chemistry and Pharmacology, Division of Laboratory Medicine, Coagulation, University and Regional Laboratories Region Skåne, Malmö, Sweden.
  • Martin M; Department of Clinical Chemistry and Pharmacology, Division of Laboratory Medicine, Coagulation, University and Regional Laboratories Region Skåne, Malmö, Sweden.
  • Astermark J; Department of Haematology, Oncology and Radiation Physics, Skåne University Hospital, and Department of Translational Medicine, Lund University, Malmö, Sweden.
  • Strandberg K; Department of Clinical Chemistry and Pharmacology, Division of Laboratory Medicine, Coagulation, University and Regional Laboratories Region Skåne, Malmö, Sweden.
Haemophilia ; 27(3): 494-500, 2021 May.
Article em En | MEDLINE | ID: mdl-33866649
INTRODUCTION: Monitoring replacement therapy with standard and extended half-life (EHL) products is challenging, since one-stage assay (OSA) and chromogenic substrate assay (CSA) results may differ significantly. Recent recommendations include local validation of each new product with recovery within 20-30%, depending on activity level. AIM: To validate factor VIII (FVIII) activity for monitoring products in clinical use on Atellica Coag and to correlate it with thrombin generation. METHODS: Plasma samples spiked with Advate® , Elocta® , Adynovi® , Nuwiq® , NovoEight® and Afstyla® (0.05, 0.20, 0.50 and 0.80 IU/ml) were analysed using Atellica Coag 360 with CSA-1 (Coatest SP) and CSA-2 (FVIII chromogenic), and OSA (Actin FS). Thrombin generation was performed using two thrombin generation assays (TGA-1 (Thrombinoscope) and TGA-2 (Technothrombin). RESULTS: All products at levels above 0.05 IU/ml, except Adynovi, showed acceptable recovery using CSA-1, whereas measurements using CSA-2 gave more results outside the target level. All products, except Afstyla, showed acceptable recovery using OSA. Correlation between CSA-1 and OSA was excellent (r2 =1.0) with biases of 6-3​2%, depending on FVIII product. A clear dose-response was seen for all thrombin generation parameters and products using both methods, except at low levels for lag time using TGA-1. With CSA-1 as an independent variable, the correlations to thrombin peak (measured with TGA-2) were good (r2  = .8-.9). CONCLUSION: Our data revealed good correlation and acceptable bias between CSA and OSA using our sets of reagents, methods and analyser in spiked samples. Thrombin generation gave good correlation to CSA-1 factor activity and is a possible complement to factor activity assays.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fator VIII / Hemofilia A Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fator VIII / Hemofilia A Idioma: En Ano de publicação: 2021 Tipo de documento: Article