[Finite element analysis of the effect of plate placement angle on cervical spine stability in anterior cervical fusion surgery].
Wu, Jian-Chao; Shi, Zheng-Wei; Pan, Yi-Xin; Li, Shao-Ping; Zhou, Jian-Wei; Wang, Yu-Liang.
Afiliação
  • Wu JC; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
  • Shi ZW; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
  • Pan YX; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
  • Li SP; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
  • Zhou JW; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
  • Wang YL; Department of Orthopaedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou 730030, Gansu, China.
Zhongguo Gu Shang ; 34(4): 372-7, 2021 Apr 25.
Article em Zh | MEDLINE | ID: mdl-33896140
OBJECTIVE: Using the method of finite element analysis, to compare the biomechanical properties between the plate deviating from the long axis of the cervical spine and the standard placement of the plate in the anterior cervical fusion surgery. METHODS: A healthy female volunteer was selected and CT scan (C1-T1) was performed. Using Mimics 19.0, Geomagic Studio 2015, Solidworks 2018, Ansys Workbench 17.2 to establish a lower cervical spine (C3-C7) model and to verify the reliability of the model. Subsequently, anterior cervical plates of different angles and lengths were placed to establish an anterior cervical discectomy fusion (ACDF) model. Applying 73.6 N axial pressure and 1 NM pure moment on C3 to make the model produce flexion, extension, lateral bending and rotation activities, observed the model stress cloud diagram and recorded the maximum stress value of the instrument and the intervertebral mobility. RESULTS: The lower cervical spine (C3-C7) finite element model was established and verified against the published literature on the range of motion (ROM) of cervical spine. Effect of steel plate offset axis on stress distribution, maximum stress value and intervertebral ROM of internal fixation apparatus was minimal, and the mechanical effect of steel plate offset was less in double section steel plate than in single section steel plate. CONCLUSION: Little effect on the mechanical stability of the cervical spine was anticipated when the anterior cervical plate was not perfectly aligned with the long axis of the cervical spine. If the tilt of the plate in clinical surgery is less than 20°, there is no need to readjust the position of the plate.