Your browser doesn't support javascript.
loading
Single-source dual energy CT to assess myocardial extracellular volume fraction in aortic stenosis before transcatheter aortic valve implantation (TAVI).
Dubourg, Benjamin; Dacher, Jean-Nicolas; Durand, Eric; Caudron, Jérôme; Bauer, Fabrice; Bubenheim, Michael; Eltchaninoff, Hélène; Serfaty, Jean-Michel.
Afiliação
  • Dubourg B; Department of Radiology, University Hospital of Rouen, 76031 Rouen, France; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France. Electronic address: drbenjamindubourg@gmail.com.
  • Dacher JN; Department of Radiology, University Hospital of Rouen, 76031 Rouen, France; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France.
  • Durand E; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France; Department of Cardiology, University Hospital of Rouen, 76031 Rouen, France.
  • Caudron J; Department of Radiology, University Hospital of Rouen, 76031 Rouen, France; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France.
  • Bauer F; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France; Department of Cardiology, University Hospital of Rouen, 76031 Rouen, France.
  • Bubenheim M; Department of Biostatistics, University Hospital of Rouen, 76031 Rouen, France.
  • Eltchaninoff H; UNIROUEN, Inserm U1096 EnVI & FHU REMOD-VHF, Normandie Université, Rouen, France; Department of Cardiology, University Hospital of Rouen, 76031 Rouen, France.
  • Serfaty JM; Department of Radiology, Institut du Thorax, INSERM, CNRS, UNIV Nantes, CHU Nantes, 44000 Nantes, France.
Diagn Interv Imaging ; 102(9): 561-570, 2021 Sep.
Article em En | MEDLINE | ID: mdl-33903056
ABSTRACT

PURPOSE:

To assess myocardial extracellular volume fraction (ECV) measurement provided by a single-source dual-energy computed tomography (SSDE-CT) acquisition added at the end of a routine CT examination before transcatether aortic valve implantation (TAVI) compared to cardiac magnetic resonance imaging (MRI). MATERIALS AND

METHODS:

Twenty-one patients (10 men, 11 women; mean age, 86±4.9 years [SD]; age range 71-92 years) with severe aortic stenosis underwent standard pre-TAVI CT with additional cardiac SSDE-CT acquisition 7minutes after intravenous administration of iodinated contrast material and myocardial MRI including pre- and post-contrast T1-maps. Myocardial ECV and standard deviation (σECV) were calculated in the 16-segments model. ECV provided by SSDE-CT was compared to ECV provided by MRI, which served as the reference. Analyses were performed on a per-segment basis and on a per-patient involving the mean value of the 16-segments.

RESULTS:

ECV was slightly overestimated by SSDE-CT (29.9±4.6 [SD] %; range 20.9%-48.3%) compared to MRI (29.1±3.9 [SD] %; range 22.0%-50.7%) (P<0.0001) with a bias and limits of agreement of +2.3% (95%CI -16.1%-+20.6%) and +2.5% (95%CI -2.1%-+7.1%) for per-segment and per-patient-analyses, respectively. Good (r=0.81 for per-segment-analysis) to excellent (r=0.97 for per-patient-analysis) linear relationships (both P<0.0001) were obtained. The σECV was significantly higher at SSDE-CT (P<0.0001). Additional radiation dose from CT was 1.89±0.38 (SD) mSv (range 1.48-2.47 mSv).

CONCLUSION:

A single additional SSDE-CT acquisition added at the end of a standard pre-TAVI CT protocol can provide ECV measurement with good to excellent linear relationship with MRI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Idioma: En Ano de publicação: 2021 Tipo de documento: Article