Your browser doesn't support javascript.
loading
Quantification of Teicoplanin Using the HPLC-UV Method for Clinical Applications in Critically Ill Patients in Korea.
Lee, Jaeok; Chung, Eun-Kyoung; Kang, Sung-Wook; Lee, Hwa-Jeong; Rhie, Sandy-Jeong.
Afiliação
  • Lee J; College of Pharmacy and Graduate School of Pharmaceutical Sciences, Ewha Womans University, Seoul 03760, Korea.
  • Chung EK; Department of Pharmacy, College of Pharmacy, Kyung Hee University, Seoul 02453, Korea.
  • Kang SW; Department of Pharmacy, Kyung Hee University Hospital at Gangdong, Seoul 05278, Korea.
  • Lee HJ; Department of Pulmonary, Allergy and Critical Care Medicine, Kyung Hee University Hospital at Gangdong, School of Medicine, Kyung Hee University, Seoul 05278, Korea.
  • Rhie SJ; College of Pharmacy and Graduate School of Pharmaceutical Sciences, Ewha Womans University, Seoul 03760, Korea.
Pharmaceutics ; 13(4)2021 Apr 17.
Article em En | MEDLINE | ID: mdl-33920524
A high-performance liquid chromatography-ultraviolet detector (HPLC-UV) method has been used to quantify teicoplanin concentrations in human plasma. However, the limited analytical accuracy of previously bioanalytical methods for teicoplanin has given rise to uncertainty due to the use of an external standard. In this study, an internal standard (IS), polymyxin B, was applied to devise a precise, accurate, and feasible HPLC-UV method. The deproteinized plasma sample containing teicoplanin and an IS of acetonitrile was chromatographed on a C18 column with an acidic mobile phase consisting of NaH2PO4 buffer and acetonitrile (78:22, v/v) by isocratic elution and detection at 220 nm. The linearity was in the range 7.8-500 mg/L calculated by the ratio of the teicoplanin signal to the IS signal. This analytical method, validated by FDA guidelines with ICH Q2 (R1), was successfully applied to analyze the plasma samples of patients in the intensive care unit for treating serious resistant bacterial infectious diseases, such as those by methicillin-resistant Staphylococcus aureus and Enterococcus faecalis. The methods suggested the potential for use in routine clinical practice for therapeutic drug monitoring of teicoplanin, providing both improved accuracy and a wide range of linearity from lower than steady-state trough concentrations (10 mg/L) to much higher concentrations.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article